Please read theentire instruction manual before using theproduct and
then save it for future reference. We reserve theright for any errors in
text or images and any necessary changes made to technical data.
In theevent of technical problems or other queries, please contact our
Customer Services.
For more information please visit www.aeotec.com for acomplete
instruction manual.
Things to consider:
• Other wireless equipment using thesame frequency band can
reduce thetransmission range.
• Therange of all wireless equipment depends on thetype of
obstacles located between thetransmitter and thereceiver
(e.g. aconcrete wall will interfere with thesignal more than
aplasterboard wall).
If you experience problems, try thefollowing:
• Turn off any other existing wireless equipment to check whether
this is thecause of theproblem.
• Reposition thewireless equipment, shorten thedistance between
thetransmitter and thereceiver or reduce thenumber of obstacles
(walls, furniture, etc.) between them.
Safety
• Never subject thesensor to high temperature, dust, heavy
vibration, impacts, humidity or moisture.
• Never attempt to dismantle or modify thesensor as it contains no
user-serviceable parts.
Product description
Battery powered, wireless water sensor for use with Zipabox Duo and
other Z-wave-system products, regardless of make.
Location
Detector
Thewater sensor can be used in
two ways. It can detect thepre-
sence of water in places that were
previously dry, or it can detect
theabsence of water where water
should be present. Thedetector
can be attached using theincluded
double-sided adhesive tape.
3. Set your Z-Wave control device to learning mode.
4. Push theZ-Wave button on thesensor to connect it to your
existing Z-Wave network.
5. If theconnection is successful, theLED indicator will shine steadily
for 10 minutes. During this period thesensor can be configured
from thecontrol device.
6. If thesensor needs to be re-configured later, you can press
the “Wake up” button. TheLED indicator will shine steadily for
10 minutes. During this period thesensor can be configured
from thecontrol device.
Uninstallation
1. Set your Z-Wave control device in removal mode and press
theZ-Wave button on thesensor to uninstall it.
2. TheLED indicator on thesensor will flash for 8 seconds if
theuninstallation was successful.
3. If theuninstallation was unsuccessful, theLED indicator will shine
steadily for 8 seconds.
Reset
Hold theZ-Wave button in for 20 seconds to reset thesensor to factory
settings. If theresetting was successful, theLED indicator will shine
steadily for 2 seconds.
Care and maintenance
• Always remove thebatteries if theproduct is not to be used for
along time.
• Clean theproduct using alightly moistened cloth. Use only mild
cleaning agents, never solvents or corrosive chemicals.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local council.
Specifications
Frequency 868.42MHz
Batteries 2×AAA/LR03
Range 30 m indoors,
100m outdoors in optimum conditions
Operating temperature–10 to +60 ºC/14–140 ºF
1. Sensor
2. Detector
Detection of rising water level
Decide on anacceptable highest water level and
place thedetector in asuitable place accordingly.
Detection of sinking water level
Decide on anacceptable lowest water level and
place thedetector in asuitable place accordingly.
Sensor
Thesensor should be placed
where it is not exposed to water or
moisture, 1 metre above thefloor
and no further than 30 metres
away from thecontrol device.
Mount thesensor with thelonger
sides perpendicular to thefloor.
1. Press thebutton on
theend of thesensor
and remove thebase.
2. Attach thebase to awall using
theincluded screws or double-
sided adhesive tape.
Note: If you mount thesensor using screws,first make sure that there
are no hidden electrical cables or water pipes in thewall/ceiling which
could be damaged by drilling themounting holes.
Installation
1. Press thebutton on theend of thesensor and
remove thebase.
2. Remove theplastic tab to activate
thebatteries. TheLED indicator on thesensor
will flash for 8 seconds.