APC Back-UPS 400

APC Back-UPS 400 bruksanvisning

(1)
  • Back-UPS ES 400/550/700
    Users Guide
    1
    Connect Battery
    For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch
    safe battery terminal.
    NOTE: Small sparks may occur during battery connection. This is normal.
    TURN the Back-UPS ES over and
    slide the battery compartment
    cover off of the battery housing.
    12
    3
    LIFT the battery out of the compartment
    and connect the black wire to the
    negative (-) battery terminal. Ensure the
    batteries are installed as shown below.
    Slide the battery compartment cover
    back onto the battery housing.
    Place the Back-UPS ES to avoid:
    - Direct sunlight
    - Excessive heat
    - Excessive humidity or contact with fluids
    Plug the Back-UPS ES power cord directly into a wall outlet; not a
    surge protector or power strip. The wall outlet should be located near
    the equipment and be easily accessible.
    Connect Modem / Phone / DSL / Fax / 10/100 Base- T/HPNA to
    Surge Protection.
    The Back-UPS protects a single line (2-wire) phone (including Digital
    Subscriber line - DSL), Home Phoneline Networking Association (HPNA)
    type equipment, modem, 10/100 Base-T Ethernet, or fax machines from
    surges when connected through the UPS as shown in the drawing below.
    Note: Telephone Cable OR Network Cable should be connected to Surge
    Protection ports. Do not connect the UPS surge protection ports to both
    Telephone and Network System cables at the same time.
    Connect Computer Cable (This is applicable for 550/700 only)
    The supplied cable and software provide automatic file saving and
    shutdown of the operating system in the case of a sustained power outage.
    Connect the cable to the Data Port of the Back-UPS ES. Connect the other
    end of the cable to the USB port on your computer. The software will
    automatically find the USB Port of your computer.
    2
    Connect Equipment
    Surge Protection Only
    These outlets provide full-time protection from surges even if
    the Back-UPS ES is switched OFF. Plug your printer, fax
    machine, scanner, or other peripherals that do not need
    battery power into these outlets.
    Battery Backup Surge Protection
    These outlets are powered whenever the Back-UPS ES is
    switched ON. During a power outage or other AC
    problems (brownouts, over-voltages), these outlets will be
    powered for a limited time by the Back-UPS ES. Plug your
    computer, monitor, and two other data-sensitive devices
    (external disk or tape drive) into these outlets.
    3
    Power On and
    Install Software
    EN 990-2375A
    Press the ON/OFF switch to power the unit
    ON.
    A single short beep and the green “Power On”
    indicator confirms that Back-UPS ES is on and
    ready to provide protection.
    The Back-UPS ES should charge for at least
    16 hours to ensure sufficient runtime. The unit
    is being charged whenever it is connected to
    AC power, whether the unit is turned ON or
    OFF.
    Install the PowerChute™ Personal
    Edition software (This is applicable for
    550/700 only.)
    Place the PowerChute Personal Edition CD-
    ROM into your computer and follow the
    installation instructions on the screen.
    Status Indicators
    The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
    Use the following table to identify the status of the Back-UPS ES.
    Status Visual Indications
    (Power On - Green)
    (Replace Battery - Red)
    Audible Indication Alarm Terminates
    When
    Power On - UPS is supplying conditioned
    AC power to the load.
    Power On LED - ON None Not applicable.
    On Battery - UPS is supplying battery
    power to the load connected to the Battery
    outlets.
    Power On LED - ON (off
    during beep)
    Beeping 4 times every
    30 seconds
    UPS transfers back to
    Power On operation, or
    when UPS is turned off.
    Low Battery Warning - UPS is supplying
    battery power to the load connected to the
    Battery outlets and the battery is near
    exhaustion.
    Power On LED - flashing Rapid beeping (every
    1/2 second)
    UPS transfers back to
    normal operation, or
    when UPS is turned off.
    Replace Battery - Battery is in need of
    charging or is at the end of its usual life and
    must be replaced.
    Power On and Replace
    Battery LEDs - Flashing
    (alternating)
    Constant tone UPS turned off with the
    power switch.
    Battery Disconnected - The battery is
    disconnected or bad battery.
    Replace Battery LED -
    flashing
    Constant tone UPS turned off with the
    power switch.
    Overload Shutdown - During On Battery
    operation a battery power supplied outlet
    overload was detected.
    None Constant tone UPS turned off with the
    power switch.
    Sleep Mode - During On Battery operation
    the battery power has been completely
    exhausted and the UPS is waiting for AC
    power to return to normal.
    None Beeping once every 4
    seconds.
    AC power is restored, or
    if AC power is not
    restored within 32
    seconds, or the UPS is
    turned off.
    See the Troubleshooting section for additional assistance.
    ©
    2013 APC by Schneider Electric
    . APC, the APC logo, Back-UPS and PowerChute are owned by Schneider Electric Industries S.A.S.,
    07/2013
    or their affiliated companies. All other trademarks are property of their respective owners.
    DATALINE OUTPUT
    TO COMPUTER USB
    FROM WALL JACK
    PORT (BACK-UPS ES 550
    AND ES 700 ONLY)
    TO DSL MODEM,
    PHONE, NETWORK
    (10/100 Base-T)
    bu366a
    CIRCUIT BREAKER
    PUSH TO RESET
    bu365d
    POWER ON/
    REPLACE BATTERY
    INDICATOR
    AC LINE
    CORD
APC Back-UPS 400

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC Back-UPS 400? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC Back-UPS 400 att svara på din fråga.

Se manualen för APC Back-UPS 400 helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 6. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om APC Back-UPS 400? Ställ din fråga här

APC Back-UPS 400 – specifikationer

Allmänt
Varumärke APC
Modell Back-UPS 400
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 4053162268388, 5053959240015, 5054533061170, 610839100309, 731304233367, 7313042333672, 731304233398, 731304233404, 7313042334044
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 400
Uteffekt 240
Nödstopp (EPO)
Ingångsfrekvens 50/60
Ljudnivå Lc IEC 45
Hörbart larm
Inmatning spänning (min) 180
Inmatning spänning (max) 266
Utgång, driftspänning (max) -
Utgång, driftspänning (min) -
Utgångsfrekvensreglering 47 - 63
Energivärdering 310
Effektivitet 98.7
Crestfaktor 3:1
Högsta strömstyrka 10
EMI / RFI-brusfiltrering
Hörbara alarmlägen Low battery alarm, Overload alarm
Vågform Sinus
UPS-topologi Vänteläge (offline)
Hålltid (min) 6
Hålltid (max) 10
Överspänningsskydd
Överspänningsskydd funktioner Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Laddningstid 16
Batteriets livslängd (max) 5
Batterikapacitet 102
Design
Produktens färg Svart
LED-indikatorer
Kabellängd 1.83
Formfaktor Compact
RoHS-efterlevnad
Certifiering BSI 1363, CE
Certifierad med Energy Star
Vikt & dimension
Vikt 5400
Bredd 230
Djup 285
Höjd 86
Förpackning
Vikt inkl. förpackning 5600
Förpackningens bredd 300
Låddjup 366
Höjd 132
Bruksanvisning
Miljökrav
Intervall för relativ operativ luftfuktighet 0 - 95
Altitud vid drift 0 - 15000
Temperaturintervall (förvaring) 0 - 40
Temperatur vid drift 0 - 40
Fuktighet (förvaring) 0 - 95
Höjd över havet i avstängt läge 0 - 15000
Anslutningar
Antal uttag AC 8AC-utgångar
AC försäljningsställen Typ E (FR)
Modem (RJ-11) portar 1
Antal LAN (RJ-45) anslutningar 1
Kabelteknik 10/100Base-T

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer