  • Troubleshooting
    Use the table below to solve minor Back-UPS ES installation or operation problems. Consult Schneider Electric IT (SEIT) Online
    Technical Support or call SEIT Technical Support for assistance with problems that cannot be resolved using the table below:
    Problem
    Specifications
    Warranty
    Service
    Input Voltage 230 Vrms Nominal
    Frequency 50 - 60 Hz (auto sensing)
    Brownout Transfer 180 Vrms, typical
    Over-voltage Transfer 266 Vrms, typical
    Output Voltage On Battery 230 Vac rms +/- 8%
    Total Amperage (8 outlets) 10 Amps (including UPS output)
    UPS Capacity (4 outlets) 400VA/240W 550VA/330W 700VA/405W
    Frequency - On Battery 50/60 Hz +/-1 Hz
    Transfer Time 6 ms typical, 10 ms maximum
    Protection and Filter AC Surge Protection Full time, 310 joules
    Phone/fax/DSL Surge
    Protection
    Single line (2-wire)
    Network Surge Protection 10/100Base-T Ethernet
    EMI/RFI Filter Full time
    AC Input Resettable circuit breaker
    Battery Type Sealed, maintenance-free lead acid
    Average Life 3 - 5 years depending on the number of discharge
    cycles and environmental temperature
    Physical Net Weight 5.4kg 6.4kg 6.8kg
    Dimensions (H x W x D) 285 x 230 x 86 mm
    (11.18” x 9.05” x 3.3 in.)
    Operating Temperature
    0
    o
    C to 40
    o
    C (32
    o
    F to 104
    o
    F)
    Storage Temperature
    -15
    o
    C to 45
    o
    C (5
    o
    F to 113
    o
    F)
    Operating Relative Humidity 0 to 95% non-condensing
    Operating Elevation 0 to 3000 m (0 to 10,000 ft)
    The standard warranty is three (3) years from the date of purchase. Schneider Electric
    IT (SEIT) standard procedure is to replace the original unit with a factory reconditioned
    unit. Customers who must have the original unit back due to the assignment of asset
    tags and set depreciation schedules must declare such a need at first contact with an
    SEIT Technical Support representative. SEIT will ship the replacement unit once the
    defective unit has been received by the repair department, or cross ship upon the
    receipt of a valid credit card number. The customer pays for shipping the unit to SEIT.
    SEIT pays ground freight transportation costs to ship the replacement unit to the
    customer.
    If the unit requires service, do not return it to the dealer. Follow these steps:
    1. Review the Troubleshooting section of the manual to eliminate common
    problems.
    2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support
    through the APC by Schneider Electric Web site, www.apc.com.
    a. Note the model number and serial number and the date of purchase. The
    model and serial numbers are located on the rear panel of the unit and are
    available through the LCD display on select models.
    b. Call SEIT Customer Support and a technician will attempt to solve the
    problem over the phone. If this is not possible, the technician will issue a
    Returned Material Authorization Number (RMA#).
    c. If the unit is under warranty, the repairs are free.
    d. Service procedures and returns may vary internationally. Refer to the APC by
    Schneider Electric Web site for country specific instructions.
    3. Pack the unit in the original packaging whenever possible to avoid damage in
    transit. Never use foam beads for packaging. Damage sustained in transit is not
    covered under warranty.
    4. Always DISCONNECT THE UPS BATTERIES before shipping. The United
    States Department of Transportation (DOT), and the International Air
    Transport Association (IATA) regulations require that UPS batteries be
    disconnected before shipping. The internal batteries may remain in the UPS.
    5. Write the RMA# provided by Customer Support on the outside of the package.
    6. Return the unit by insured, pre-paid carrier to the address provided by Customer
    Support.
    Order Replacement Battery
    Replace with an APC by Schneider Electric qualified battery. Replacement batteries
    can be ordered from www.apc.com (valid credit card required). For Back-UPS ES 400,
    order APCRBC106 as directed by SEIT Technical Support. For Back-UPS ES 550,
    order RBC2. For Back-UPS ES 700, order RBC17.
    Item Specification BE400 BE550 BE700
    165 mm
    (6.50 in.)
    Wall Mounting Template
    Wall Mount of UPS
    APC by Schneider Electric IT
    Customer Support Worldwide
    For country specific customer support, go to the APC by Schneider Electric Web site,
    www.apc.com.
    Solution
    Back-UPS ES will not turn on.
    No power available at the Surge Protection
    Only outlets.
    Connected equipment loses power.
    The Power On indicator is lit and the Back-
    UPS ES is beeping four times every 30
    seconds.
    The Power On indicator flashes once per
    second and the Back-UPS ES beeps once per
    second at the same time.
    Inadequate runtime.
    Connect the battery (see Connect Battery) and ensure power is available at the wall
    outlet.
    Reduce the amount of equipment plugged into Surge Protection Only outlets.
    Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
    controlling the outlet (if any) is in the ON position.
    Ensure the equipment you want to stay powered during a power failure is plugged
    into the Battery Backup/Surge Protection outlets and NOT the Surge Protection Only
    outlets.
    Make sure the equipment plugged into the Battery Backup/Surge Protection outlets
    of the unit are not overloading the capacity of the unit. Try removing some of the
    equipment and see if the problem continues.
    The Back-UPS ES is operating normally.
    The Back-UPS ES can only operate on battery power for a limited amount of time.
    The unit will eventually turn off when the available battery power has been used.
    Allow the unit to recharge for 16 hours before continuing use of the unit.
    The output waveform is designed for computers and computer-related equipment. It
    is not designed for use with motor-type equipment.
    Contact SEIT Technical Support for further troubleshooting.
    The Back-UPS ES is operating normally and using battery power. Once On Battery,
    you should save your current work, power down your equipment, and turn the unit
    OFF. Once normal power is restored, you may turn the unit back ON and power your
    equipment.
    The Back-UPS ES is about to shut off due to a low battery charge condition! When
    the unit beeps once every second, the battery has about 2 minutes of power
    remaining. Immediately power down your computer and turn the unit OFF. When
    normal power returns, the unit will recharge the battery.
    Allow the unit to charge by leaving it plugged into the wall for at least 16 hours.
    As a battery ages, the amount of runtime available will decrease. You can replace
    the battery by ordering one at www.apc.com. Batteries also age prematurely if the
    Back-UPS ES is placed near excessive heat.
    The U
    PS can be mounted vertically or horizontally to a wall surface. Use the template below to
    position the mounting fasteners (not supplied). Wall mount the UPS as follows;
    1. Hold this page against the wall in the desired mounting location.
    2. Use thumbtacks or tape to hold this page in place against the wall. Use a sharp nail or pin to
    puncture the center of each template circle to mark the wall.
    3. Install the mounting fasteners at the marked locations. Leave the head of both fasteners 8
    mm (5/16) out from the face of the wall. The fasteners must be able to support 6.8 Kg.
    4. Mount the UPS by positioning the key-hole slots over the mounting fasteners heads. For ver-
    tical mounting, slide the UPS down into place. For horizontal mounting, turn it slightly counter-
    clockwise until it is securly in place.
    Battery is disconnected or AC power is not available at the
    wall outlet.
    Surge Protection Only outlets have been overloaded.
    AC power not available at the wall outlet.
    Equipment is connected to the Surge Protection Only
    outlets.
    The Back-UPS ES is overloaded.
    PowerChute Personal Edition software has performed a
    shutdown due to a power failure.
    The Back-UPS ES has exhausted its available battery
    power.
    Connected equipment does not accept the step-
    approximated sine waveform of the Back-UPS ES.
    The Back-UPS ES may require service.
    The Back-UPS ES is using battery.
    Battery capacity is low (about 2 minutes of use remaining).
    The battery is not fully charged.
    Battery is near the end of useful life.
APC Back-UPS 400

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC Back-UPS 400? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC Back-UPS 400 att svara på din fråga.

Se manualen för APC Back-UPS 400 helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 6. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om APC Back-UPS 400? Ställ din fråga här

APC Back-UPS 400 – specifikationer

Allmänt
Varumärke APC
Modell Back-UPS 400
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 4053162268388, 5053959240015, 5054533061170, 610839100309, 731304233367, 7313042333672, 731304233398, 731304233404, 7313042334044
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 400
Uteffekt 240
Nödstopp (EPO)
Ingångsfrekvens 50/60
Ljudnivå Lc IEC 45
Hörbart larm
Inmatning spänning (min) 180
Inmatning spänning (max) 266
Utgång, driftspänning (max) -
Utgång, driftspänning (min) -
Utgångsfrekvensreglering 47 - 63
Energivärdering 310
Effektivitet 98.7
Crestfaktor 3:1
Högsta strömstyrka 10
EMI / RFI-brusfiltrering
Hörbara alarmlägen Low battery alarm, Overload alarm
Vågform Sinus
UPS-topologi Vänteläge (offline)
Hålltid (min) 6
Hålltid (max) 10
Överspänningsskydd
Överspänningsskydd funktioner Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Laddningstid 16
Batteriets livslängd (max) 5
Batterikapacitet 102
Design
Produktens färg Svart
LED-indikatorer
Kabellängd 1.83
Formfaktor Compact
RoHS-efterlevnad
Certifiering BSI 1363, CE
Certifierad med Energy Star
Vikt & dimension
Vikt 5400
Bredd 230
Djup 285
Höjd 86
Förpackning
Vikt inkl. förpackning 5600
Förpackningens bredd 300
Låddjup 366
Höjd 132
Bruksanvisning
Miljökrav
Intervall för relativ operativ luftfuktighet 0 - 95
Altitud vid drift 0 - 15000
Temperaturintervall (förvaring) 0 - 40
Temperatur vid drift 0 - 40
Fuktighet (förvaring) 0 - 95
Höjd över havet i avstängt läge 0 - 15000
Anslutningar
Antal uttag AC 8AC-utgångar
AC försäljningsställen Typ E (FR)
Modem (RJ-11) portar 1
Antal LAN (RJ-45) anslutningar 1
Kabelteknik 10/100Base-T

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer