APC Back-UPS 500VA

APC Back-UPS 500VA bruksanvisning

(1)
  • 1
    Place the Back-UPS to avoid:
    Direct sunlight
    Excessive heat
    Excessive humidity or contact with fluids
    bu054a
    ON/OFF and
    LED Status
    Indicator
    Battery backup and
    surge protected outlets
    2
    3
    990-3333B-005 © 2009 American Power Conversion Corp.
    All other trademarks are property of their respective owners.
    APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
    Connect the Battery and Turn on the Unit
    Connect the battery to the UPS before use. To connect the battery:
    Pull the top of the battery connector lever out of the unit, until the lever is horizontal.
    Push the battery connector lever completely into the unit, until the end of the lever is flush with the rear panel.
    Press ON/OFF to turn on the unit.
    A single short beep, and the green “Power On” indicator confirms that the Back-UPS is on and ready to provide
    protection.
    The Back-UPS should charge for at least 10 hours to ensure sufficient runtime. The unit is being charged
    whenever it is connected to utility power, whether the unit is turned ON or OFF.
    Status Indicators
    The Back-UPS indicates its operating status using a combination of visual and audible indicators.
    Power On LED Buzzer Condition
    On Off On-line - Back-UPS is supplying conditioned utility power
    to the connected equipment
    On (Off during 4
    beeps)
    4 beeps repeated
    every 30 seconds
    On-Battery - Back-UPS is supplying battery power
    Flashing Rapid Beeping
    (every 1/2 second)
    Low Battery Warning - The Back-UPS has 1.5 minutes of
    remaining battery power
    Flashing Constant tone Bad Battery Detected - Battery needs to be charged, or is
    at end of life. (See Battery Replacement.)
    Off Short beep every
    4 seconds
    Low Battery Shutdown - During On Battery operation the
    battery power was almost completely exhausted, and the
    Back-UPS is waiting for utility power to return to normal
    Off Constant Tone On Battery Overload - Connected equipment requires
    more power than provided by the Back-UPS battery.
    Unplug devices one at a time to remove overload, if not
    corrected Contact APC Technical Support
    On Constant Tone On Line Overload - The power drawn by the connected
    equipment exceeds the power capacity of the Battery
    Backup
    Flashing Chirp every 2
    seconds
    Charger Warning -Back-UPS has experienced an internal
    problem, but continues to power the load. Contact APC
    Technical Support
    Off Constant Tone Charger Fault - Back-UPS has an internal problem, and is
    no longer powering the load. Contact APC Technical
    Support
    Adjusting Transfer
    Voltage and Sensitivity
    Settings
    Automatic Voltage Regulation boosts the utility voltage
    when it drops below safe levels. This allows the
    equipment plugged into the unit to operate during low
    voltage conditions, conserving the battery power in the
    event of a power outage.
    The Back-UPS will switch to battery power if the input
    voltage level becomes too low for the Automatic
    Voltage Regulation to compensate, or if the utility
    power is distorted.
    If the Back-UPS switches to battery power too
    frequently or too infrequently, adjust the transfer
    voltage and sensitivity settings:
    1. Ensure the Back-UPS is off. Plug it into utility
    power.
    2. Press and hold ON/OFF until the LED repeatedly
    flashes. The unit is now in Program Mode.
    3. Release the button. The LED will flash once,
    twice, or three times per second, indicating the
    current setting. See Transfer Voltage and
    Sensitivity Settings.
    4. Press ON/OFF within two seconds to change the
    setting. Each time the button is pressed, the LED
    will flash at a different rate: once, twice, or three
    times per second, indicating the new setting.
    Continue pressing the button until the desired
    setting is reached. If the button is not pressed
    within five seconds, the Back-UPS will exit the
    Program Mode.
    5. To exit Program Mode, release the button and
    wait for the LED to stop flashing.
    Connect Equipment
    Battery Backup Surge Protection
    These outlets are powered whenever the Back-UPS is switched
    ON. During a power outage, or other utility problems (brownouts,
    over-voltages), these outlets will be powered for a limited time by
    the Back-UPS. Plug the computer and monitor into these two
    outlets.
    Connect AC Power Cord
    Plug the Back-UPS power cord into a wall outlet, not a surge
    protector or power strip. The outlet should be near the equipment
    and easily accessible.
    Back-UPS
    ®
    RS 500
    BR500CI-AS User Guide
    Transfer Voltage and Sensitivity Settings
    LED Flashing
    Transfer Voltage
    Setting
    Input Voltage
    Range
    (For Utility
    Operation)
    Usage
    Once per second Low 155 - 280 The Back-UPS will switch to battery power less often. Use with equipment that is not
    sensitive to low or high level voltage levels or minor voltage waveform distortions.
    Twice per second Medium
    (factory default)
    160 -280 Default, use in normal conditions.
    Three times per second
    High 165 - 270 The Back-UPS will switch to battery power during any small fluctuation in voltage.
    Use with equipment that is sensitive to low or high level voltage levels or minor
    voltage waveform distortions.
    bu053a
APC Back-UPS 500VA

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC Back-UPS 500VA? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC Back-UPS 500VA att svara på din fråga.

Se manualen för APC Back-UPS 500VA helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 8.4. Den här manualen är tillgänglig på följande språk: Engelsk, Kinesisk. Behöver du hjälp eller har du en fråga om APC Back-UPS 500VA? Ställ din fråga här

APC Back-UPS 500VA – specifikationer

Allmänt
Varumärke APC
Modell Back-UPS 500VA
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 731304269793, 7313042697934
Språk Engelsk, Kinesisk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 500
Uteffekt 300
Inmatning spänning (min) -
Inmatning spänning (max) 230
Utgång, driftspänning (min) -
Utgång, driftspänning (max) 230
Ingångsfrekvens 50/60
Energivärdering 240
Antal ingångsfaser 1
Antal utgångsfaser 3
Överspänningsskydd
Hörbart larm
Anslutningar
Antal uttag AC 4AC-utgångar
AC försäljningsställen C13 coupler
Uttag C14 coupler
Design
Kabellängd 1.8
Formfaktor Mini tower
Produktens färg Svart
RoHS-efterlevnad
LED-indikatorer Energiljus
Övrigt
Output anslutningstyp IEC 320 C13
Förpackningsstorlek (B x D x H) 190 x 291 x 257
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Laddningstid 10
Normal drifttid vid halv belastning 1
Normal drifttid vid full belastning 70
Vikt & dimension
Vikt 4900
Bredd 115
Djup 213
Höjd 185
Miljökrav
Temperaturintervall (förvaring) -15 - 45
Intervall för relativ operativ luftfuktighet 0 - 95
Fuktighet (förvaring) 0 - 95
Altitud vid drift 0 - 3000
Höjd över havet i avstängt läge 0 - 15000
Förpackning
Vikt inkl. förpackning 5500

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.