APC Back-UPS 650

APC Back-UPS 650 bruksanvisning

(1)
  • Safety
    Specifications
    Connect the Battery
    The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop!
    Connect the Battery” label that covers the outlets. Prior to connecting any equipment
    to the unit, connect the battery cable to the unused battery terminal. It is normal for
    small sparks to be seen when the battery cable is connected to the battery terminal.
    Wall Mount Installation
    Horizontal installation, use 2 screws 7.3" (186.3 mm) apart.
    Vertical installation, use 2 screws 5.4" (137.2 mm) apart.
    Allow 5/16" (8 mm), of the screw to protrude from the wall.
    Replace Battery
    Use only approved APC replacement battery cartridges.
    Deliver used batteries to a battery replacement facility in the packaging provided by
    APC with the replacement battery cartridge. To order replacement battery cartridges
    contact APC.
    Connect Equipment
    Battery Backup + Surge Protection Outlets
    Battery backup outlets provide protection to connected equipment when the
    Back-UPS is turned on and connected to utility power.
    Battery backup outlets receive power from the Back-UPS for a limited period of time
    when a power outage, or brownout condition occurs.
    Battery backup outlets provide protection from power surges or spikes.
    Connect a computer, monitor and other peripheral devices to the outlets.
    Surge Protection Outlets
    Surge protection outlets provide protection to connected equipment when the
    Back-UPS is connected to utility power, and is switched on or off.
    Surge protection outlets provide protection from power surges or spikes.
    Connect a printer, scanner or other peripheral devices that do not need to remain on
    during power outages, or utility problems to the surge protection outlets.
    Connect Network
    The Back-UPS protects equipment connected to a 10/100 Base-T ethernet, from
    power surges when connected through the Back-UPS coaxial connectors.
    PowerChute
    ®
    Personal Edition Software
    Overview
    Use PowerChute Personal Edition software to configure the UPS settings.
    Protect your computer and other equipment during a power outage. During a power
    outage, PowerChute will save any open files on your computer and safely shut it
    down. When power is restored, it will restart the computer.
    Configure the UPS to use features such as power-saving outlets, shutdown
    configuration, and alarms.
    Monitor the UPS for power usage and power events.
    Note: PowerChute is only compatible with a Windows operating system. If you are
    using a Mac OSX, use the native shutdown feature to protect your system. See the
    documentation provided with your computer.
    Installation
    Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port
    on your computer.
    If the Back-UPS came with a PowerChute CD, insert the CD into your computer and
    follow the on-screen instructions
    If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and
    download the software free of charge.
    Turn On the Back-UPS
    Press the POWER ON button located on the top of the Back-UPS. The Power On/
    Replace Battery LED will illuminate and a single short beep will be audible to
    indicate that the Back-UPS is providing protection for connected equipment.
    The Back-UPS battery charges fully during the first 16 hours while connected to
    utility power. The Back-UPS battery will charge while the Back-UPS is switched on
    or off and is connected to utility power. Do not expect full battery run capability
    during the initial charge time.
    If the red Building Wiring Fault LED located on the side of the Back-UPS
    illuminates, do not operate the Back-UPS. Have a qualified electrician correct the
    building wiring fault.
    Warranty
    The standard warranty is 3 years in the USA and Canada, 2 years in all other regions
    from the date of purchase. APC standard procedure is to replace the original unit with
    a factory reconditioned unit. Customers who must have the original unit back due to
    assigned asset tags and set depreciation schedules must declare such a need at first
    contact with APC Technical Support. APC will ship the replacement unit once the
    defective unit is received by the repair department or cross-ship upon the provision of
    a valid credit card number. The customer pays for shipping to APC, and APC pays
    ground freight transportation costs back to the customer.
    This unit is intended for indoor use only.
    Do not operate this unit in direct sunlight, in
    contact with fluids, or where there is excessive
    dust or humidity.
    Connect the Back-UPS power cord directly to a
    wall outlet. Do not use a surge protector or an
    extension cord.
    Input
    Voltage 120 Vac Nominal
    Frequency 60 Hz +
    3
    Brownout Transfers 92 Vac Typical
    Over-voltage Transfer 139 Vac Typical
    Output
    UPS Capacity
    (4 battery backup outlets)
    BE450G: 450 VA, 257 W;
    BE550G: 550 VA, 330 W;
    BE650G1: 650 VA, 390 W
    Total Amperage (all outlets) 12 A (including UPS output)
    Voltage - On Battery 115 Vac ± 8%
    Frequency - On Battery 60 Hz +
    1
    Transfer Time 6 ms Typical, 10 ms maximum
    Protection
    and
    Filtering
    AC Surge Protection Full time, 340 Joules
    EMI/RFI Filter Full time
    AC Input Resettable circuit breaker
    Battery
    Type Sealed, maintenance-free, lead acid
    BE450G: RBC114
    BE550G: RBC110
    BE650G1: RBC17
    Average Life 3 - 5 years depending on the number of
    discharge cycles and environmental
    temperature
    Physical
    Net Weight Replacement battery cartridge
    BE450G: 10 lb (4.7 kg)
    BE550G: 12 lb (5.5 kg)
    BE650G1: 14 lb (6.2 kg)
    Dimensions
    Length x Width x Height
    12 in x 7 in x 3 in
    30 cm x 18 cm x 9 cm
    Operating Temperature 32º F to 104º F (0º C to 40º C)
    Storage Temperature 5º F to 113º F (–15º C to 45º C)
    Operating Relative Humidity 0 to 95% non-condensing humidity
    Operating Elevation 0 to 10,000 ft (0 to 3000 m)
    EMC
    Compliance
    This device complies with part 68 and part 15 of the FCC rules.
    Operation is subject to the following two conditions: (1) This device
    may not cause harmful interference, and (2) This device must accept any
    interference received, including interference that may cause undesired
    operation.
    Press the battery compartment cover
    release tab located on the rear side of the
    unit. Slide the battery cover off.
    Connect the battery cable securely to the
    battery terminal.
    Reinstall the battery compartment cover.
    Be sure that the release tab locks into place.
    bu064a
    bu065a
    bu066a
    bu202a
    Back-UPS
    Battery Backup + Surge Protection
    Surge Protection
    bu201a
    CAUTION-Refer to bottom
    of unit for safety markings.
    Circuit
    Breaker
    Building
    Wiring Fault
    PowerChute
    USB Port
    Network
    Out
    Push to
    Reset
    Network
    In
    User Manual Back-UPS
    ®
    BE 450G/550G/650G1
APC Back-UPS 650

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC Back-UPS 650? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC Back-UPS 650 att svara på din fråga.

Se manualen för APC Back-UPS 650 helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 9.8. Den här manualen är tillgänglig på följande språk: Engels. Behöver du hjälp eller har du en fråga om APC Back-UPS 650? Ställ din fråga här

APC Back-UPS 650 – specifikationer

Allmänt
Varumärke APC
Modell Back-UPS 650
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 731304285144, 731304285458
Språk Engels
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 650 VA
Energivärdering 320 J
Ingångsfrekvens 50/60 hz
Uteffekt 400 W
Överspänningsskydd Ja
Ljudnivå Lc IEC 45 dB
Hörbart larm Ja
Övrigt
Utspänning (Volt) 230 V
Batterityp RBC17
Överbelastningsskydd Ja
Gränssnitt USB
Anslutningsdetaljer ingång IEC C13
Produktstorlek (BxDxH) 91 x 284 x 165 mm
Förpackningsstorlek (B x D x H) 185 x 415 x 494 mm
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Laddningstid 8 h
Design
Kabellängd 2 m
Produktens färg Beige
LED-indikatorer Ja
Certifiering A-tick, C-tick, CE, GOST, NEMKO, RoHS.
Anslutningar
Seriella portar 1
Antalet output IEC jumpers 2
Antal USB 2.0 anslutningar 1
Vikt & dimension
Vikt 6030 g
Bredd 91 mm
Djup 284 mm
Höjd 165 mm
Miljökrav
Temperatur vid drift 0 - 40 ° C
Intervall för relativ operativ luftfuktighet 5 - 95
Altitud vid drift 0 - 9000 m
Temperaturintervall (förvaring) -15 - 45 ° C
Fuktighet (förvaring) 5 - 95
Höjd över havet i avstängt läge 0 - 4500 m
Förpackning
Vikt inkl. förpackning 7310 g

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2021 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer