APC BE400-GR-OC

APC BE400-GR-OC bruksanvisning

(1)
  • Back-UPS ES 400/550/700
    User’s Guide
    ®
    1
    Connect Battery
    For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch
    safe battery terminal.
    NOTE: Small sparks may occur during battery connection. This is normal.
    TURN the Back-UPS ES over and
    slide the battery compartment
    cover off of the battery housing.
    12
    3
    LIFT the battery out of the compartment
    and connect the black wire to the
    negative (-) battery terminal. Ensure the
    batteries are installed as shown below.
    Slide the battery compartment cover
    back onto the battery housing.
    Place the Back-UPS ES to avoid:
    - Direct sunlight
    - Excessive heat
    - Excessive humidity or contact with fluids
    Plug the Back-UPS ES power cord directly into a wall outlet; not a
    surge protector or power strip. The wall outlet should be located near
    the equipment and be easily accessible.
    Connect Modem / Phone / DSL / Fax / 10/100 Base- T/HPNA to
    Surge Protection.
    The Back-UPS protects a single line (2-wire) phone (including Digital
    Subscriber line - DSL), Home Phoneline Networking Association (HPNA)
    type equipment, modem, 10/100. Base-T Ethernet, or fax machines from
    surges when connected through the UPS as shown in the drawing below.
    Note:
    Telephone Cable OR Network Cable should be connected to Surge
    Protection ports. Do not connect the UPS surge protection ports to both
    Telephone and Network System cables at the same time.
    Connect Computer Cable (This is applicable for 550/700 only)
    The supplied cable and software provide automatic file saving and
    shutdown of the operating system in the case of a sustained power outage.
    Connect the cable to the Data Port of the Back-UPS ES. Connect the other
    end of the cable to the USB port on your computer. The software will
    automatically find the USB Port of your computer.
    2
    Connect Equipment
    Surge Protection Only
    These outlets provide full-time protection from surges even if
    the Back-UPS ES is switched OFF. Plug your printer, fax
    machine, scanner, or other peripherals that do not need
    battery power into these outlets.
    Battery Backup
    Surge Protection
    These outlets are powered whenever the Back-UPS ES is
    switched ON. During a power outage or other utility
    problems (brownouts, over-voltages), these outlets will be
    powered for a limited time by the Back-UPS ES. Plug your
    computer, monitor, and two other data-sensitive devices
    (external disk or tape drive) into these outlets.
    DATALINE OUTPUT
    TO COMPUTER USB
    FROM WALL JACK
    PORT (BACK-UPS ES 550
    AND ES 700 ONLY)
    TO DSL MODEM,
    PHONE, NETWORK
    CIRCUIT BREAKER
    PUSH TO RESET
    (10/100 Base-T)
    3
    Power On and
    Install Software
    990-2373 Copyright 2005 American Power Conversion Corp.
    Press the ON/OFF switch to power the unit
    ON.
    A single short beep and the green “Power On”
    indicator confirms that Back-UPS ES is on and
    ready to provide protection.
    The Back-UPS ES should charge for at least
    16 hours to ensure sufficient runtime. The unit
    is being charged whenever it is connected to
    utility power, whether the unit is turned ON or
    OFF.
    Install the PowerChute Personal
    ®
    Edition software (This is applicable for
    550/700 only.)
    Place the PowerChute Personal Edition CD-
    ROM into your computer and follow the
    installation instructions on the screen.
    Status Indicators
    The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
    Use the following table to identify the status of the Back-UPS ES.
    Status Visual Indications
    (Power On - Green)
    (Replace Battery - Red)
    Audible Indication Alarm Terminates
    When
    Power On
    - UPS is supplying conditioned
    utility power to the load.
    Power On LED - ON None Not applicable.
    On Battery
    - UPS is supplying battery
    power to the load connected to the Battery
    outlets.
    Power On LED - ON (off
    during beep)
    Beeping 4 times every
    30 seconds
    UPS transfers back to
    Power On operation, or
    when UPS is turned off.
    Low Battery Warning
    - UPS is supplying
    battery power to the load connected to the
    Battery outlets and the battery is near
    exhaustion.
    Power On LED - flashing Rapid beeping (every
    1/2 second)
    UPS transfers back to
    normal operation, or
    when UPS is turned off.
    Replace Battery
    - Battery is in need of
    charging or is at the end of its usual life and
    must be replaced.
    Power On and Replace
    Battery LEDs - Flashing
    (alternating)
    Constant tone UPS turned off with the
    power switch.
    Battery Disconnected
    - The battery is
    disconnected or bad battery.
    Replace Battery LED -
    flashing
    Constant tone UPS turned off with the
    power switch.
    Overload Shutdown
    - During On Battery
    operation a battery power supplied outlet
    overload was detected.
    None Constant tone UPS turned off with the
    power switch.
    Sleep Mode
    - During On Battery operation
    the battery power has been completely
    exhausted and the UPS is waiting for utility
    power to return to normal.
    None Beeping once every 4
    seconds.
    Utility power is restored,
    or if utility power is not
    restored within 32
    seconds, or the UPS is
    turned off.
    See the Troubleshooting section for additional assistance.
    All other trademarks are property of their respective owners.
    APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
    AC LINE
    CORD
    POWER ON/
    REPLACE BATTERY
    INDICATOR
APC BE400-GR-OC

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC BE400-GR-OC? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC BE400-GR-OC att svara på din fråga.

Se manualen för APC BE400-GR-OC helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 5.6. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om APC BE400-GR-OC? Ställ din fråga här

APC BE400-GR-OC – specifikationer

Allmänt
Varumärke APC
Modell BE400-GR-OC
Produkt Avbrottsfri strömförsörjning (UPS)
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 400
Uteffekt 240
Energivärdering 310
Ljudnivå Lc IEC 45
Hörbart larm
Övrigt
Ingångsspänning (Volt) 230
Utgångar (Notering) 230
Utspänning (Volt) 230
Anslutningsdetaljer utgång 4 x CEE 7
4 x CEE 7
Mac-kompatibel
Produktstorlek (BxDxH) 230 x 285 x 86
Förpackningsstorlek (B x D x H) 300 x 366 x 132
Filtrering
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Laddningstid 16
Anslutningar
Antal LAN (RJ-45) anslutningar 1
Design
Produktens färg Svart
LED-indikatorer
Certifiering CE, GOST, NEMKO
Vikt & dimension
Vikt 5400
Förpackning
Vikt inkl. förpackning 5600
Miljökrav
Temperatur vid drift 0 - 40
Intervall för relativ operativ luftfuktighet 0 - 95
Altitud vid drift 0 - 15000
Temperaturintervall (förvaring) 0 - 40
Fuktighet (förvaring) 0 - 95
Höjd över havet i avstängt läge 0 - 15000

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.