APC BE650G

APC BE650G bruksanvisning

(1)
  • Back-UPS ES 650
    Users Guide
    1
    2
    3
    Connect Battery
    Equipment
    Power On and
    Install Software
    990-4995 Copyright © 2007 American Power Conversion Corp.
    All other trademarks are property of their respective owners.
    Surge Protection
    These outlets provide full-time protection from surges even if the
    Back-UPS ES is switched OFF. Plug your printer, fax machine,
    scanner, or other peripherals that do not need battery power into
    these outlets.
    Battery Back-up + Surge Protection
    These outlets are powered whenever the Back-UPS ES is
    switched ON. During a power outage or other utility problems
    (brownouts, over-voltages), these outlets will be powered for a
    limited time by the Back-UPS ES. Plug your computer,
    monitor, CD-ROM drive and two other data-sensitive devices
    such as an external disk or tape drive, or Home Phoneline
    Networking Association (HPNA) device into these outlets.
    Press the ON/OFF switch to power the unit
    ON.
    A single short beep and the green “Power On”
    indicator confirms the Back-UPS ES is on and
    ready to provide protection.
    The Back-UPS ES should charge for at least 16
    hours to ensure sufficient runtime. The unit is
    being charged whenever it is connected to utility
    power, whether the unit is turned ON or OFF.
    If the red Building Wiring Fault indicator (located
    on the end near the power cord) is lit, your
    building wiring presents a shock hazard that
    should be corrected by a qualified electrician.
    Install the PowerChute
    ®
    Personal
    Edition
    software
    Place the PowerChute Personal Edition CD-
    ROM into your computer and follow the
    installation instructions on the screen.
    w
    w
    w
    .apc.com
    ®
    APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
    The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
    Use the following table to identify the status of the Back-UPS ES.
    Status
    Visual Indications
    (Power On - Green)
    (Replace Battery - Red)
    Audible Indication Alarm Terminates
    When
    Power On - UPS is supplying conditioned
    utility power to the load.
    Power On pushbutton -
    ON (lit)
    None Not applicable.
    On Battery - UPS is supplying battery
    power to the load connected to the Battery
    outlets.
    Power On pushbutton -
    ON (off during beep)
    Beeping 4 times every
    30 seconds
    UPS transfers back to
    Power On operation, or
    when UPS is turned off.
    Low Battery Warning - UPS is supplying
    battery power to the load connected to the
    battery outlets, and the battery is near
    exhaustion.
    Replace Battery indicator
    is flashing
    Rapid beeping (every
    1/2 second)
    UPS transfers back to
    normal operation, or
    when UPS is turned off.
    Replace Battery - The battery is
    disconnected.
    The battery is in need of charging, or is at
    the end of its usual life and must be
    replaced.
    Replace Battery indicator
    is Flashing
    Power On and Replace
    Battery indicators -
    flashing (alternating)
    Constant tone
    Constant tone
    UPS is turned off with
    the power switch.
    Overload Shutdown - During On Battery
    operation a battery power supplied outlet
    overload was detected.
    None Constant tone UPS is turned off with
    the power switch.
    Sleep Mode - During On Battery operation
    the battery power has been completely
    exhausted and the UPS is waiting for utility
    power to return to normal.
    None Beeping once every 4
    seconds
    Utility power is restored,
    or if utility power is not
    restored within 32
    seconds, or the UPS is
    turned off.
    Building Wiring Fault - Your building
    wiring presents a shock hazard that should
    be corrected by a licensed electrician.
    Building Wiring Fault LED
    (red) - ON
    None UPS is unplugged, or
    UPS is plugged into a
    properly wired outlet.
    Status Indicators
    ®
    See the Troubleshooting section for additional assistance.
    For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
    battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.
    Turn the Back-UPS ES over and press in the
    release tab. Slide the plastic battery cover
    off of the Back-UPS.
    Insert the battery back into the compartment.
    Slide the plastic battery cover until the release
    tab locks into place.
    Connect the red battery wire firmly to
    the positive (+) battery terminal.
    1 2 3
    Connect
    Connect Modem / Phone / DSL / Fax / 10/100Base-T / HPNA / Cable Modem / CATV
    or DSS to Surge Protection
    The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line -
    DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, 10/100
    Base-T Ethernet, or fax machines from surges when connected through the UPS as
    shown in the drawing below.
    The UPS also protects a cable modem, CATV converter, or DSS receiver from surges
    when it is connected through the UPS coaxial connectors as shown in the drawing below.
    Place the Back-UPS ES to avoid:
    - Direct sunlight
    - Excessive heat
    - Excessive humidity or contact with fluids
    Plug the Back-UPS ES power cord directly into a wall outlet; not into a surge
    protector or power strip.
    Connect Computer Cable
    The supplied cable and software provide automatic file saving and shutdown of the
    operating system in the case of a sustained power outage.
    Connect the cable to the Data Port of the Back-UPS ES. Connect the other end of the
    cable to the USB port on your computer. The software will automatically find the
    computer’s USB Port.
    BATTERY DOOR
    RELEASE TAB
    Power On/Off
    Switch & Indicator
    Replace
    Battery
    Indicator
    NOTE:
    Replace Battery Indicator is only visible when illuminated.
    Circuit Breaker
    Push to Reset
    From Wall
    Outlet
    Dataline outpu to
    em, Fax, or
    t DSL,
    Mod Network
    (10/100BASE-T)
    Data Port
    Cable output to Cable Modem,
    CATV converter or DSS input
    Cable input from Internet Service
    Provider (ISP), CATV or DSS
APC BE650G

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om APC BE650G? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av APC BE650G att svara på din fråga.

Se manualen för APC BE650G helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 9.9. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om APC BE650G? Ställ din fråga här

APC BE650G – specifikationer

Allmänt
Varumärke APC
Modell BE650G
Produkt Avbrottsfri strömförsörjning (UPS)
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 650
Uteffekt 390
Energivärdering 365
Ingångsfrekvens 50/60
Övrigt
Ingångsspänning (Volt) 120
Utspänning (Volt) 120
Anslutningsdetaljer utgång 8 x NEMA 5-15R
Anslutningsdetaljer ingång NEMA 5-15P
Produktstorlek (BxDxH) 320 x 177 x 90
Vikt (imperial) 14.3
Omgivningstemperatur vid drift 0 - 40
Förpackningsstorlek (B x D x H) 445 x 259 x 148
Icke-fungerande relativ luftfuktighet (icke kondenserande) 0 - 95
Batteri
Hot-swap batteri
Normal drifttid vid halv belastning 13.3
Normal drifttid vid full belastning 3.7
Laddningstid 16
Design
Kabellängd 1.8
LED-indikatorer
Certifiering FCC Part 15 Class B/FCC Part 68/TUV/UL 1778
Vikt & dimension
Vikt 6500
Förpackning
Vikt inkl. förpackning 7500
Miljökrav
Temperatur vid drift 0 - 40
Intervall för relativ operativ luftfuktighet 5 - 95
Altitud vid drift 0 - 3000
Temperaturintervall (förvaring) -15 - 45
Fuktighet (förvaring) 5 - 95
Logistikdata
Pall, kvantitet 72

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer