Bosch WTA74100GB

Bosch WTA74100GB bruksanvisning

(1)
  • 1
    Contents
    ʋ Safety instructions ........................................................................................................................ 1
    ʋ Connections on the dryer ........................................................................................................... 2
    ʋ Notes on installation .................................................................................................................... 3
    ʋ Installation options ....................................................................................................................... 4
    ʋ Notes on installation .................................................................................................................... 6
    ʋ Installing more than one dryer ................................................................................................... 7
    Safety instructions
    We recommend that you route the exhaust air directly into the open air through an exhaust
    air duct.
    Where an exhaust air duct is routed to the open air, a drain check valve must be fitted
    (prevents air from flowing back).
    Only install the air extraction system as described in these instructions.
    The air extraction system must not exceed the specified pressure losses, see page 3.
    Only use materials and parts specified in the instructions.
    Clean the exhaust air duct regularly, at least once a year.
    When operating the dryer without an exhaust air duct, the following must also be observed:
    Ensure that the room is well ventilated, otherwise energy consumption and drying time will
    increase.
    Ensure that the room is well ventilated a risk of damage caused by moisture, e.g. to walls,
    furniture.
    Do not cover the exhaust air opening (leave approx. 1 m of free space around the exhaust
    air opening).
    2
    Connections on the dryer
    Connections for an exhaust air duct are located on the back panel and on the left side panel
    of the dryer.
    Back panel connection
    The exhaust air opening on the back panel is open when the
    dryer is delivered (bayonet ring).
    The exhaust air opening on the left side panel is sealed with
    a cover.
    Left side panel connection
    1. Remove the cover on the side panel.
    2. Remove the bayonet ring from the back panel and attach it
    to the opening on the side panel.
    3. Seal the opening in the back panel with the cover.
    Condensation outlet
    If there is a high level of condensation in the exhaust air duct, it is advisable to fix a
    condensation collector (standard) or a drain hole with a diameter of approximately 3 mm
    to the lowest part of the exhaust air duct.
    1.
    2.
    3
    Notes on installation
    Exhaust air duct
    All standard products can be used for the exhaust air duct:
    flexible pipes
    galvanised metal ducts or pipes
    connectors, adapters, and diverters for flat duct systems and pipe systems
    wall boxes for evaporation into the open air or into a ventilation shaft
    adapters on rectangular ducts
    rectangular ducts or plastic pipes
    backpressure flap
    The material must be heat resistant up to 80 °C and moisture resistant.
    Pressure losses
    The type and length of the exhaust air duct, particularly elbows or bends with small radii, can
    impede the air flow. a Keep diameter reductions and pressure losses (resistance) to a
    minimum.
    The following must be avoided:
    long exhaust air ducts
    exhaust air ducts with small diameters
    exhaust air ducts with many bends and elbows.
    Pressure losses through friction
    Duct or pipe friction resistance, i.e. friction on the inside of the exhaust air duct, affects the
    air flow as follows:
    the smoother the internal wall
    the larger the diameter of the internal wall
    the shorter the pipe
    the lower the friction resistance.
    Pressure losses due to fixtures
    The exhaust air encounters further resistance through fixtures built into the pipe, e.g.
    diverters (bends, elbows, angles), wall boxes with grids or backpressure flaps.
    Installation for pipe connection - inside diameter = 100 mm
    In order to ensure the minimum required air flow, a certain pressure loss (resistance) must
    not be exceeded.
    The permissible total pressure loss in an exhaust air duct must not exceed a certain value.
    This is calculated as the sum of all individual pressure loss values for the straight pieces
    and fixtures in the exhaust air duct.
    The value for the maximum permissible total pressure loss for an exhaust air duct is 50*.
    Installation for pipe connection - inside diameter = 100 mm
    If the pipe connection has an inside diameter > 100 mm and a total pressure loss greater
    than 50*, increase the inside diameter of the pipe connection
    * To determine the total pressure loss see table a page 6.
    4
    Installation options
    Route the exhaust air duct in such a way that the dryer cannot draw the moist, warm
    exhaust air back in again.
    The outlet for the exhaust air must be designed or positioned in such a way as to
    prevent any additional backpressure (e.g. from a direct ingress of wind) on the
    escaping exhaust air, e.g. by using a 9bend, facing down a page 7.
    The outlet for the exhaust air duct must be no more than 2.5 m higher than the exhaust
    air opening on the appliance.
    Installation options for the exhaust air duct:
    Through a wall box into the open air
    Example: pipe connection - inside diameter = 100 mm,
    smooth
    A = straight piece (1.0 m) 4
    B = curved pipe (R = 200 mm) 4
    C = straight piece (1.5 m) 6
    D = pipe elbow 19
    E = telescopic wall box with grid 14
    Total pressure loss 47
    Directly into the open air
    Route the exhaust air directly into the open air via an exhaust
    air pipe through an open window.
    Example:
    Pipe connection - inside diameater = 100 mm, flexible pipe,
    corrugated
    A = curved pipe (R = 300 mm) 7
    B = straight piece (1.5 m) 18
    C = curved pipe (R = 100 mm) 10
    D = straight piece (0.5 m) 6
    Total pressure loss 41
    Through a wall box into chimneys or ventilation shafts
    It is not permitted to connect the exhaust air duct to chimneys which are connected
    to gas or coal-fired ovens/cookers or gas-fired heating systems.
    If the appliance is being connected to a moisture-insulated ventilation shaft the
    responsible chimney sweep must be informed and the approval of the local building
    department (building supervision office) or the owner of the building must be obtained.
    If other appliances are operated in the room where the appliance is installed or in
    adjoining rooms, e.g. gas-fired heating systems, gas-fired boilers, coal-fired ovens
    connected to a chimney, or open fireplaces, a vacuum may be created, leading to
    waste gases being sucked back a risk of poisoning.
    In every case, have safe operation confirmed by the responsible chimney sweep, boiler
    engineer, ventilation specialist, etc.
    1.
    2.
    3.
Bosch WTA74100GB

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om Bosch WTA74100GB? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av Bosch WTA74100GB att svara på din fråga.

Se manualen för Bosch WTA74100GB helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 6.4. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om Bosch WTA74100GB? Ställ din fråga här

Bosch WTA74100GB – specifikationer

Allmänt
Varumärke Bosch
Modell WTA74100GB
Produkt Torktumlare
EAN 4242002842189
Språk Engelsk
Filtyp PDF
Design
Apparatens placering Fristående
Laddning Frontmatad
Torksystem Ventilerande
Produktens färg Vit
Gångjärnssida Höger
Kontrolltyp Buttons, Rotary
Drum volym 112
Inbyggd display
Sladdlängd 1.45
Certifiering CE, VDE
Prestanda
Trumkapacitet 6
Torkklass -
Periodlängd 114
Ljudnivå Lc IEC 66
Skrynkelreducering
Skrynkelskydd cykel 90
Justerbar centrifugeringshastighet
Minsta centrifugeringshastighet 800
Maximal centrifugeringshastighet 1400
- Tajmad
Ergonomi
Fördröjd start timer
Innerbelysning
Indikator för LED-programstadie
Strömtillförsel
Energiklass C
Ansluten effekt 2200
AC-inspänning 220-240
Växelström Frekvens 50
Ström märkning 10
Strömförbrukning i avslaget läge 0.1
Energiförbrukning 3.45
Årlig energiförbrukning 427
Värmekälla Elektrisk
Vikt & dimension
Bredd 598
Djup 630
Höjd 842
Vikt 45000
Förpackning
Förpackningens bredd 630
Låddjup 680
Höjd 870
Vikt inkl. förpackning 46000
Torkprogram
Tidsinställt torkprogram

Vanliga frågor

Nedan hittar du de vanligaste frågorna om Bosch WTA74100GB .

Är din fråga inte listad? Ställ din fråga här

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer