    Automatic Voltage Regulators
    increase low or decrease high voltage to a computer
    safe 110/120 volts. The AVR automatically provides
    battery back-up power if line voltage drops below 90
    volts or exceeds 140 volts.
    AVR
    INCONSISTENT
    UTILITY POWER
    CONSISTENT
    SAFE POWER
    Min
    V
    ESTIMATE RUN_TIMEINPUT
    LOAD CAPACITY
    BATT. CAPACITY
    OUTPUT
    BATTERY
    A.V.R
    FAULT
    NORMALNORMAL
    SILENT
    OVER
    LOAD
    100
    IN OUT
    5
    6
    9
    10
    11
    12
    UNPACKING
    Inspect the UPS upon receipt. The box should contain the following:
    (1) UPS unit; (1) User’s manual; (1) PowerPanel
    ®
    Personal Edition software CD; (1) USB device cable; (1) Telephone
    cable; (1) Warranty registration card; (1) Coaxial Cable
    OVERVIEW
    The CP850AVRLCD / CP1000AVRLCD provides automatic voltage regulation for
    inconsistent utility power. The CP850AVRLCD / CP1000AVRLCD features 890
    /1080 Joules of surge protection, and provides battery backup during power
    outages. The CP850AVRLCD / CP1000AVRLCD ensures consistent power to your
    computer system and its included software will automatically save your open files
    and shutdown your computer system during a utility power loss.
    AUTOMATIC VOLTAGE REGULATOR
    The CP850AVRLCD / CP1000AVRLCD stabilizes inconsistent utility
    power. The incoming utility power may be damaging to important data
    files, but with Automatic Voltage Regulation, the computer will not
    experience damaging voltage levels. An Automatic Voltage Regulator
    automatically increases low or decreases high voltage to a consistent,
    computer safe 110v/120v. The unit’s powerful sealed lead-acid
    batteries will provide power only if the incoming voltage drops below
    90v or increases above 140v.
    HARDWARE INSTALLATION GUIDE
    1.Your new UPS may be used immediately upon receipt. However, recharging the batteries
    for at least 16 hours is recommended to ensure that the battery’s maximum charge capacity
    is achieved. A loss of charge may occur during shipping and storage. To recharge the
    batteries, simply leave the unit plugged into an AC outlet. The unit will charge in both the
    ON as well as the OFF position.
    2.With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage
    device (Zip drive, Jazz drive, Tape drive, etc…) into the battery power supplied outlets. Plug your peripheral
    equipment (printer, scanner, speakers) into the full-time surge protection outlets. DO NOT plug a laser printer, paper
    shredder, copier, space heater, vacuum or other large electrical device into the UPS. The power demands of
    these devices will overload and possibly damage the unit.
    3. To surge protect a network connection, connect a network cable from the wall jack outlet to the IN jack of the UPS.
    Then connect a network cable from the OUT jack on the UPS to the network device.
    4.Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet). Make sure the wall branch outlet is protected by
    a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).
    The warranty prohibits the use of extension cords, outlet strips, and surge strips.
    5.Press the power switch to turn on the unit. The unit will beep twice and the power on indicator will illuminate.
    6.If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the
    UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make
    sure the circuit breaker is depressed and then turn the UPS on.
    7.To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
    8.To store your UPS for an extended period, cover it and store with the battery fully charged. While in storage recharge
    the battery every three months to ensure battery life.
    SOFTWARE INSTALLATION GUIDE
    Windows Users
    When you first get a new CyberPower UPS, you'll need to install some software on your computer to control your UPS
    and begin using it.
    Installing PowerPanel
    ®
    Personal Edition
    1. Place the CD in your CD drive and wait for the setup wizard to begin. If the wizard does not begin, go to your CD drive
    in "My Computer" and open the "PowerPanel
    ®
    PE " folder and double click "Setup.exe".
    2. Follow the instructions on your screen and complete the installation. The default settings offered by the installation
    wizard are acceptable for most users and can be changed at any time if necessary.
    3. After the setup is complete plug the USB cord from your CyberPower UPS to an available USB port on your computer.
    4. You are now ready to begin using the PowerPanel
    ®
    Personal Edition software.
    Mac Users
    When you first get a new CyberPower UPS, you'll need to configure the Mac UPS function to control your UPS and
    begin using it.
    Configuring the "Energy Saver" UPS Function
    1. Plug the USB cord from your CyberPower UPS to an available USB port on your computer..
    2. Go to "System Preferences" and open the "Energy Saver" control panel.
    3. Select settings for "UPS".
    You are now ready to configure the settings for the UPS.
    CP850AVRLCD / CP1000AVRLCD
    User’s Manual
    K01-0000023-00
    (SAVE THESE INSTRUCTIONS)
    This manual contains important safety instructions. Please read and follow all instructions carefully during installation
    and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
    CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free
    of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
    CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. No user
    serviceable parts are inside except the battery.
    CAUTION! Some components can be energized by the battery when unit is unplugged.
    CAUTION! UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an
    outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
    CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the
    battery or installing a computer component.
    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life
    support or medical applications. DO NOT use in any circumstance that would affect operation or safety of any life
    support equipment or with any medical applications or patient care.
    DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an
    aquarium. Condensation from the aquarium can cause the unit to short out.
    DO NOT USE WITH LASER PRINTERS! The power demands of these devices will overload and possibly damage the
    unit.
    DESCRIPTION
    1 Power Switch
    Used as the master on/off switch for equipment connected to the battery
    power supplied outlets.
    2 Power On Indicator
    This LED is under the power switch. It illuminates when the utility condition
    is normal and the UPS outlets are providing power, free of surges and
    spikes.
    3 LCD Module Display.
    High resolution and intelligent LCD display shows all the UPS information
    with icons and messages. For more information please check the
    “Definitions for Illuminated LCD Indicators” section.
    4 LCD Display Toggle/Selected Switch
    The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and Estimated Run
    Time. The toggle frequency is set to one time per second. Holding the switch for more than two seconds while running
    on battery will silence the buzzer.
    5 Battery and Surge Protected Outlets
    The unit has five battery powered/surge protected outlets for connected equipment and ensures temporary uninterrupted
    operation of your equipment during a power failure.
    6 Full-Time Surge Protection Outlets
    The unit has four always on surge suppression outlets.
    7 Electrical Wiring Fault Indicator
    This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or
    reversed wiring. If this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an
    electrician check to ensure the outlet is properly wired. The unit will not provide surge protection without being plugged
    into a grounded and properly wired wall outlet.
    8 Communication Protection Ports
    Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet
    connection.
    9 Circuit Breaker
    Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.
    10 Serial/USB Ports to PC
    The USB and serial port allow communication from the UPS to the computer. The UPS communicates its status to the
    PowerPanel
    ®
    Personal Edition software when connected with a USB port. The serial port is only used with third party
    UPS software such as the Microsoft UPS Power Option of Windows 2000, XP, and Vista. For information on configuring
    and using the serial port and the Microsoft UPS Power Option or for information regarding ordering a standard serial
    cable, please contact technical support at tech@cyberpowersystems.com.
    Note: The serial port and USB port cannot be used to control two computers concurrently. Only one port will function at
    a time.
    11 Coax/Cable/DSS Surge Protection
    The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.
    12 Input Power Cord
    Connect the unit into an AC outlet.
    CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the
    battery under the supervision of personnel knowledgeable of batteries and their precautions.
    CAUTION! Use only the specified type of battery. See your dealer for replacement batteries.
    CAUTION! The battery may present a risk of electrical shock. Do not dispose of battery in a fire as it may explode.
    Follow all local ordinances regarding proper disposal of batteries. Almost any retailer that sells lead-acid batteries
    collects used batteries for recycling, as required by most state laws.
    CAUTION! Do not open or mutilate the batteries. Released electrolyte is harmful to skin and eyes and may be toxic.
    CAUTION! A battery can present a high risk of short circuit current and electrical shock. Take the following precautions
    before replacing the battery:
    1.Remove all watches, rings or other metal objects.
    2.Only use tools with insulated handles.
    3.Do not lay tools or metal parts on top of battery or any terminals.
    4.Wear rubber gloves and boots.
    5.Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. CONTACT WITH A
    GROUNDED BATTERY
    CAN RESULT IN ELECTRICAL SHOCK!
    Model CP850AVRLCD CP1000AVRLCD
    Capacity 850VA / 510W 1000VA / 600W
    Input Voltage on Utility 90V to 140V
    Input Frequency 60 Hz ± 3 Hz
    On-Battery Output Voltage 120Vac ± 5%
    Transfer Time 4ms Typical
    Max. Load for UPS Outlets 850VA / 510W 1000VA / 600W
    Max. Load for Full-Time 
    Surge Protection outlets (9 Outlets)
    12 Amps
    On-Battery Output Wave Form Simulated Sine Wave Form
    Operating Temperature + 32°F to 95° F / 0° C to 35° C
    Operating Relative Humidity 0 to 95% NON-CONDENSING
    Size (L x W x H)
    10.24" x 4.33" x 8.70"
    26.0 x 11.0 x 22.6cm
    Net Weight 15.8 lbs 16.7 lbs
    Typical Battery Recharge Time 8 hours typical from total discharge
    Typical Battery Life 3 to 6 years, depending on number of discharge/recharge cycles
    Battery Type Spill-proof, Maintenance-free, sealed lead-acid
    Safety Approvals UL1778(UPS), cUL107., FCC/DoC Class B
    Model iMac G4
    Desktop PC  Desktop PC Desktop PC  Desktop PC
    with 17" LCD Monitor with 19" LCD Monitor with 21" LCD Monitor with CRT Monitor
    CP850AVRLCD 87 minutes 49 minutes 42 minutes 34 minutes 32 minutes
    CP1000AVRLCD 89 minutes 50 minutes 42 minutes 35 minutes 34 minutes
    IMPORTANT SAFETY WARNINGS
    INSTALLING YOUR UPS SYSTEM
    BASIC OPERATION
    TROUBLE SHOOTING
    DEFINITIONS FOR ILLUMINATED LED INDICATORS
    Limited Warranty and Connected Equipment Guarantee
    TECHNICAL SPECIFICATIONS
    1. Turn off and unplug all connected equipment.
    2. Turn the UPS off and unplug it from the AC power source.
    3. Turn the UPS upside down.
    4. Remove the retaining screw.
    5. Slide the battery compartment cover completely off of the unit.
    6. Remove the batteries from the compartment.
    7. Disconnect the battery wires from the batteries.
    8. Install the replacement batteries by connecting the red wire
    and black wire to the same color wires from the battery pack.
    9. Put the batteries back into the compartment.
    10. Slide back the battery compartment cover and tighten the
    retaining screw.
    11. Recharge the UPS for 8-16 hours to fully charge the battery.
    The LCD display indicates a variety
    of UPS operational conditions. All
    descriptions apply when the UPS is
    plugged into an AC outlet and turned
    on or when the UPS is on battery.
    INPUT voltage meter: This meter measures the AC voltage that the UPS
    system is receiving from the utility wall outlet. The UPS is designed, through
    the use of automatic voltage regulation, to continuously supply connected
    equipment with stable, 110/120 output voltage. In the event of a complete
    power loss, severe brownout, or over-voltage, the UPS relies on its internal
    battery to supply consistent 110/120 output voltage. The INPUT voltage meter
    can be used as a diagnostic tool to identify poor-quality input power.
    OUTPUT voltage meter: This meter measures, in real time, the AC voltage
    that the UPS system is providing to the computer, such as normal line mode,
    AVR mode, and battery back up mode.
    Note: The OUTPUT voltage meter shows the status of the battery back up
    outlets.
    ESTIMATE RUN TIME: This displays the run time estimate of the UPS with
    the current battery capacity and load.
    NORMAL icon: This icon appears when the UPS is working under normal conditions.
    BATTERY icon: During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps
    followed by a pause) to indicate the UPS is operating from its internal batteries. During a prolonged brownout or
    blackout, the alarm will sound continuously (and the BATT.CAPACITY meter shows one 20% capacity segment shaded)
    to indicate the UPS’s batteries are nearly out of power. You should save files and turn off your equipment immediately.
    AVR (Automatic Voltage Regulator) icon: This icon appears whenever your UPS is automatically correcting too low or
    too high AC line voltage without using battery power. This is a normal, automatic operation of your UPS, and no action is
    required on your part.
    SILENT MODE icon:This icon appears whenever the UPS is in silent mode. The buzzer does not beep during silent
    mode until the battery reaches low capacity.
    OVER LOAD icon: This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To
    clear the overload, unplug some of your equipment from the battery-supplied outlets until the icon turns off and the alarm
    stops.
    FAULT icon: This icon appears if there is a problem with the UPS. Contact CyberPower Systems at
    tech@cyberpowersystems.com for further help and support.
    BATT. CAPACITY meter: This meter displays the approximate charge level (in 20% increments) of the UPS’s internal
    battery. During a blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the
    charge level decreases.
    LOAD CAPACITY meter: This meter displays the approximate output load level (in 20% increments) of the UPS’s
    battery outlets.
    Alarm
    Condition
    On Off Off Normal
    On On/Off
    2 beeps
    per 30 seconds
    On On/Off Rapid beeps
    On On/Off Long beeps
    On On None
    POWER
    ON
    WIRING
    FAULT
    Utility failure—The UPS is providing battery power to the battery power-
    supplied outlets.
    Utility failure—The UPS is providing battery power.The rapid beeps mean
    that the battery will run out of charge within a few minutes.
    Battery overload—Occurs in the battery power-supplied outlets. Turn off
    the UPS and unplug at least one piece of equipment from the UPS. Wait
    10 seconds, press the circuit breaker reset button, then turn the UPS on.
    Electrical wiring fault—This means there’s a wiring problem within the
    utility AC power outlet. A wiring problem could be a bad ground, missed
    ground, or reversed wiring. You should disconnect all equipment from
    the outlet and have it checked by an electrician.
    REPLACING THE BATTERY
    DEFINITIONS FOR ILLUMINATED LCD INDICATORS
    REMINDER: Batteries are consider HAZARDOUS WASTE and must be disposed
    of properly. Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as required by most
    state laws.
    Additional troubleshooting information can be found at
    www.cyberpowersystems.com/support.htm
    Problem Possible Cause Solution
    Full-time surge protection outlets
    stop providing power to equipment.
    Circuit breaker button is projecting
    from the side of the unit.
    Circuit breaker has
    tripped due to an
    overload.
    Turn the UPS off and unplug at least one piece of equipment.
    Wait 10 seconds, reset the circuit breaker by depressing the
    button, and then turn the UPS on.
    The UPS does not perform
    expected runtime.
    Recharge the battery by leaving the UPS plugged in.
    Contact CyberPower Systems about replacement batteries at
    tech@cyberpowersystems.com
    Battery is slightly worn out.
    Battery not fully charged.
    The UPS will not turn on.
    The unit failed a self test.
    Turn the UPS off. Wait 10 seconds and then turn the UPS on.
    The unit is not connected to an
    AC outlet.
    The unit must be connected to a 110/120v 60Hz outlet.
    The battery is worn out.
    Contact CyberPower Systems about replacement batteries at
    tech@cyberpowersystems.com
    Mechanical problem.
    Contact CyberPower Systems at
    tech@cyberpowersystems.com
    Power Panel
    ®
    Personal Edition is
    inactive (all icons are gray).
    The USB cable is not
    connected.
    Connect the USB cable to the UPS unit and an open USB port
    on the back of the computer. You must use the cable that
    came with the unit.
    The USB cable is connected
    to the wrong port.
    Check the back of the computer for an additional USB port.
    Move the cable to this port.
    The unit is not providing
    battery power.
    Shutdown your computer and turn the UPS off. Wait 10
    seconds and turn the UPS back on. This should reset the unit.
    EXPECTED RUNTIME IN MINUTES
    (Due to the differences in computer components, the runtime will vary.)
    Read the following terms and conditions carefully before using the CyberPower CP850AVRLCD / CP1000AVRLCD (the
    “Product”). By using the Product you consent to be bound by and become a party to the terms and conditions of this
    Limited Warranty and Connected Equipment Guarantee (together referred to as this “Warranty”). If you do not agree to
    the terms and conditions of this Warranty, you should return the Product for a full refund prior to using it.
    Who is Providing this Warranty?
    CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty.
    What Does This Warranty Cover?
    This warranty covers defects in materials and workmanship in the Product under normal use and conditions. It also
    covers equipment that was connected to the Product and damaged because of the failure of the Product.
    What is the Period of Coverage?
    This warranty covers the Product for three years and connected equipment for as long as you own the Product.
    Who Is Covered?
    This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the Product.
    How Do You Get Service?
    1.Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 5555 12th Ave. E., STE 110, Shakopee,
    MN 55379 or send us an e-mail message at claims@cyberpowersystems.com for instructions.
    2.When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment.
    Have information on all applicable insurance or other resources of recovery/payment that are available to the Initial
    Customer and Request a Claim Number.
    3.You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect.
    4.Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost
    estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the
    Claim Number on the shipping label or include it with the product. You must prepay all shipping costs, you are
    responsible for packaging and shipment, and you must pay the cost of the repair estimate.
    How Long Do I Have To Make A Claim?
    All claims must be made within ten days of the occurrence.
    What Will We Do To Correct Problems?
    CyberPower will inspect and examine the Product.
    If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or,
    if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time,
    CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is
    required).
    If it appears that our Product failed to protect any equipment plugged into it, we will also send you forms for making your
    claim for the connected equipment. We will repair or replace the equipment that was damaged because of the failure of
    our Product or pay you the fair market value (NOT REPLACEMENT COST) of the equipment at of the time of the
    damage. We will use Orion Blue Book, or another a third-party valuation guide, or eBay, craigslist, or other source to
    establish that amount. Our liability is limited to CP850AVRLCD - $250,000; CP1000AVRLCD-$350,000.
    Who Pays For Shipping?
    We pay when we send items to you; you pay when you send items to us.
    What Are Some Things This Warranty Does Not Cover?
    1.This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the
    Product or any data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of
    software.
    2.This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of
    the Product or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been
    improper operation or maintenance, or use with items not designed or intended for use with the Product, such as laser
    printers, appliances, aquariums, medical or life support devices, etc.
    .
    What Other Limitations Apply?
    1.This Warranty does not apply unless the Product and the equipment that was connected to it were connected to
    properly wired and grounded outlets (including compliance with electrical and safety codes of the most current
    electrical code), without the use of any adapters or other connectors.
    2.The Product must have been plugged directly into the power source and the equipment connected to the Product must
    be directly connected to the Product and not “daisy-chained” together in serial fashion with any extension cords,
    another Product or device similar to the Product, surge suppressor, or power tap. Any such installation voids the
    Limited Warranty.
    3.The Product and equipment connected to it must have been used properly in a suitable and proper environment and in
    conformance with any license, instruction manual, or warnings provided with the Product and the equipment
    connected to it.
    4.The Product must have been used at all times within the limitations on the Product’s VA capacity.
    What are the Limitations?
    The sole and exclusive remedies of the Initial Customer are those provided by this Warranty.
    The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage spikes or
    impulses from lightning or other power transients. If it can be shown that a voltage spike lasting longer than 1ms has
    occurred, the occurrence will be deemed outside the rated capabilities of the Product and the Limited Warranty is void.
    CyberPower Does Not Cover or Undertake Any Liability in Any Event for Any of the Following:
    1.Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software.
    2.Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and
    code-compliant 120 volt power lines in the United States and Canada; transients, surges or spikes on standard
    telephone land lines, PBX telephone equipment lines or Base 10T Ethernet lines, when properly installed and
    connected. (This exclusion applies, for example, to fluctuations in data transmission or reception, by CATV or RF
    transmission or fluctuations, or by transients in such transmission.)
    3.Damage from any circumstance described as excluded above with respect to the Product.
    4.Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of
    either the product or the Connected Equipment.
    5.CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment
    Guarantee. CyberPower excludes any liability for direct, indirect, special, incidental or consequential damages,
    whether for damage to or loss of property [EXCEPT FOR (AND ONLY FOR) the specific limited agreement of
    CyberPower to provide certain warranty benefits regarding "Connected Equipment" under this Warranty], loss of
    profits, business interruption, or loss of information or data. NOTE: Some States or Provinces do not allow the
    exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
    6.The Product is not for use in high-risk activities or with aquariums. The Product is not designed or intended for use in
    hazardous environments requiring fail-safe performance, or for use in any circumstance in which the failure of the
    Product could lead directly to death, personal injury, or severe physical or property damage, or that would affect
    operation or safety of any medical or life support device (collectively, "High Risk Activities"). CyberPower expressly
    disclaims any express or implied warranty of fitness for High Risk Activities or with aquariums. CyberPower does not
    authorize use of any Product in any High Risk Activities or with Aquariums. ANY SUCH USE IS IMPROPER AND IS A
    MISUSE OF THE PRODUCT.
    What is the Fine Print?
    The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded.
    CyberPower is the warrantor under this Limited Warranty.
    For further information please feel free to contact CyberPower at Cyber Power Systems (USA), Inc. 5555 12th Ave E.,
    STE 110, Shakopee, MN 55379; call us at (877) 297-6937; or send us an e-mail message at
    TO REPLACE THE BATTERY
    PLUG IN
CyberPower CP1000AVRLCD

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om CyberPower CP1000AVRLCD? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av CyberPower CP1000AVRLCD att svara på din fråga.

Se manualen för CyberPower CP1000AVRLCD helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 8.5. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om CyberPower CP1000AVRLCD? Ställ din fråga här

CyberPower CP1000AVRLCD – specifikationer

Allmänt
Varumärke CyberPower
Modell CP1000AVRLCD
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 100177360966, 163120851201, 649532010004, 6495320100044
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 1000
Uteffekt 600
Energivärdering 1080
Ingångsfrekvens 60
Svarstid (medel) 4
Hörbart larm
Övrigt
Anslutningsdetaljer utgång NEMA 5-15R
Anslutningsdetaljer ingång NEMA 5-15P
Produktstorlek (BxDxH) 108 x 267 x 222.25
Vikt (imperial) 16
Omgivningstemperatur vid drift 32 - 95
Dimension (B x D x H) (imperial) 4.25 x 10.5 x 8.75
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Normal drifttid vid halv belastning 6
Normal drifttid vid full belastning 1
Laddningstid 8
Utbytbara batteripatroner BB - HR9-12
Design
Formfaktor Tower
Certifiering UL1778, cUL 107.1, FCC DOC Class B
Anslutningar
Seriella portar 1
Modem (RJ-11) portar 1
Antal LAN (RJ-45) anslutningar 1
Antal USB 2.0 anslutningar 2
Vikt & dimension
Vikt 7257
Miljökrav
Temperatur vid drift 0 - 40
Intervall för relativ operativ luftfuktighet 0 - 95

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer