CyberPower CPS425SL

CyberPower CPS425SL bruksanvisning

(1)
  • CPS425SL/CP425HG
    CP500SL/CP500HG
    CP425G
    Users Manual
    K01-0000081-00
    (SAVE THESE INSTRUCTIONS)
    This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
    Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
    CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
    contaminants. (Please see specifications for acceptable temperature and humidity range).
    CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside.
    CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
    CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
    grounded. If you need to de-energize this equipment, turn off and unplug the unit.
    CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
    CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
    accordance with the National Electric Code, ANSI/NFPA 70.
    DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
    applications. DO NOT use in any circumstance that would affect operation and safety of life support equipment, any medical applications or
    patient care.
    DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
    from the aquarium can cause the unit to short out.
    UNPACKING
    Inspect the UPS upon receipt. The box should contain the following:
    (a) UPS unit x 1 (b) User’s manual x 1 (c) PowerPanel
    ®
    Personal Edition software CD x 1 (for CPS425SL/CP425HG, CP500SL/CP500HG only)
    (d) USB device cable x 1 (for CPS425SL/CP425HG, CP500SL/CP500HG only) (e) Telephone cable x 1 (f) Warranty registration card x 1
    SYSTEM FUNCTION BLOCK DIAGRAM
    HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
    1. Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (425VA/255W for CPS425SL/CP425HG and
    CP425G, 500VA/300W for CP500SL/CP500HG). If the rated capacities of the unit are exceeded, an overload condition may occur and
    cause the UPS unit to shut down or the circuit breaker to trip.
    2. There are many factors that can affect the amount of power that your computer system will require. For optimal system performance keep
    the load below 80% of the unit’s rated capacity.
    HARDWARE INSTALLATION GUIDE
    1. Your new UPS may be used immediately upon receipt. As a loss of charge may occur
    during shipping and storage, the unit should be plugged into a wall outlet to charge
    battery for at least 8 hours.
    2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any
    other peripherals requiring battery backup into the battery power supplied outlets. Plug
    the other peripheral equipment (printer, scanner, speakers) into the full-time surge protection outlets. DO NOT plug a laser printer, paper
    shredder, copier, space heater, vacuum, sump pump or other large electrical device into the “Battery and Surge Protected Outlets”.
    The power demands of these devices will overload and possibly damage the unit.
    3. To protect a fax, phone or modem, connect a telephone cable from the wall jack outlet to the IN jack
    of the UPS. Connect a telephone cable from one of the UPS OUT jacks to the modem port on the computer.
    The other UPS OUT jack can be used to protect a telephone or fax machine.
    4. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is
    protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
    conditioner, refrigerator, copier, etc…). The warranty prohibits the use of extension cords, outlet strips,
    and surge strips.
    5. Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will “beep” twice.
    6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at
    least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
    7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
    8. To store the UPS for an extended period, cover it and store with the battery fully charged. While in storage, recharge the battery every three
    months to ensure battery life.
    DESCRIPTION
    Battery and Surge Protected Outlets
    The unit has four battery powered/surge suppression outlets to ensure temporary uninterrupted operation of your equipment during a power
    failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or other large electrical device into
    the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.)
    Full-Time Surge Protection Outlets
    The unit has four surge suppression outlets.
    Power Switch
    Press the power button to turn the UPS on or off.
    Power On Indicator (green)
    This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
    Electrical Wiring Fault Indicator (red)
    This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If
    this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will
    not provide surge protection without being plugged into a grounded and properly wired wall outlet.
    Communication Protection Ports
    Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11)
    Circuit Breaker
    Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.
    USB Port to PC (for CPS425SL/CP425HG and CP500SL/CP500HG; CP425G has no USB port)
    The ports allow connection and communication between the USB port on the computer and the UPS unit. The UPS communicates its
    status to the PowerPanel
    ®
    Personal Edition software. The USB interface is also compatible with the Power Management applications
    provided by Windows Vista, Mac OS X, and Linux.
    Note: To install PowerPanel
    ®
    Personal Edition Software the computer will need Microsoft
    R
    Internet Explore 6.0 or higher installed.
    Outlets Designed for AC Adapters
    The UPS unit has four widely-spaced outlets, so AC power adapter blocks can be plugged into the UPS without overlapping adjacent outlets.
    Problem Possible Cause Solution
    Full-time surge protection outlets
    stop providing power to
    equipment. Circuit breaker
    button is projecting from the side
    of the unit.
    Circuit breaker has tripped due to an
    overload.
    Turn the UPS off and unplug at least one piece of
    equipment. Wait 10 seconds, reset the circuit breaker by
    depressing the button, and then turn the UPS on.
    Battery not fully charged. Recharge the battery by leaving the UPS plugged in.
    The UPS does not perform
    expected runtime.
    Battery is worn out.
    Contact CyberPower Systems about replacement batteries
    at tech@cyberpowersystems.com
    The on/off switch is designed to
    prevent damage from rapidly turning
    it off and on.
    Turn the UPS off. Wait 10 seconds and then turn the UPS
    on.
    The unit is not connected to an AC
    outlet.
    The unit must be connected to a 110/120V 60Hz outlet.
    The battery is worn out.
    Contact CyberPower Systems about replacement batteries
    at tech@cyberpowersystems.com
    The UPS will not turn on.
    Mechanical problem.
    Contact CyberPower Systems at
    tech@cyberpowersystems.com
    The USB cable is not connected.
    Connect the USB cable to the UPS unit and an open USB
    port on the back of the computer. You must use the cable
    that came with the unit.
    The USB cable is connected to the
    wrong port.
    Check the back of the computer for an additional USB port.
    Move the cable to this port.
    PowerPanel
    ®
    Personal Edition is
    inactive (all icons are gray).
    * CP425G has no USB port.
    The unit is not providing battery
    power.
    Shutdown your computer and turn the UPS off. Wait 10
    seconds and turn the UPS back on. This should reset the
    unit.
    Additional troubleshooting information can be found at “Support” at
    www.CPSww.com
    EXPECTED RUNTIME IN MINUTES
    (Due to the differences in computer components, the runtime will vary.)
    Model
    Mac mini
    with 15” LCD
    Desktop PC
    with 17” LCD Monitor
    Desktop PC
    with 19” LCD Monitor
    Desktop PC
    with 21” LCD Monitor
    Desktop PC
    with 17” CRT Monitor
    CPS425SL/CP425HG
    CP425G
    18 10 8 7 5
    CP500SL/CP500HG
    30 17 12 10 7
    BASIC OPERATION
    INSTALLING YOUR UPS SYSTEM
    TROUBLESHOOTING
    IMPORTANT SAFETY WARNINGS
    EMI Filter
    Surge
    Suppressor
    Charger
    AC/DC
    Battery
    Inverter
    Input Output
    Normal Mode
    Battery Mode
CyberPower CPS425SL

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om CyberPower CPS425SL? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av CyberPower CPS425SL att svara på din fråga.

Se manualen för CyberPower CPS425SL helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 7.1. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om CyberPower CPS425SL? Ställ din fråga här

CyberPower CPS425SL – specifikationer

Allmänt
Varumärke CyberPower
Modell CPS425SL
Produkt Avbrottsfri strömförsörjning (UPS)
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 425
Uteffekt 230
Energivärdering 585
Ingångsfrekvens 60
Svarstid (medel) 4
Hörbart larm
Inmatning spänning (min) -
Inmatning spänning (max) -
Utgång, driftspänning (min) -
Utgång, driftspänning (max) -
UPS-topologi Vänteläge (offline)
EMI / RFI-brusfiltrering
Övrigt
Anslutningsdetaljer ingång NEMA 5-15P
Produktstorlek (BxDxH) 248 x 83 x 159
Vikt (imperial) 8
Omgivningstemperatur vid drift 32 - 95
Dimension (B x D x H) (imperial) 9.75 x 3.25 x 6.25
Batteri
Batteriteknik Slutna blybatterier (VRLA)
Normal drifttid vid halv belastning 9
Normal drifttid vid full belastning 2
Laddningstid 8
Utbytbara batteripatroner BB - BP4-12
Anslutningar
Seriella portar 1
Modem (RJ-11) portar 3
Antal uttag AC 6AC-utgångar
AC försäljningsställen NEMA 5–15R
Design
Produktens färg Svart
Certifiering UL1778, cUL, FCC DOC B
Formfaktor Compact
Vikt & dimension
Vikt 3628
Miljökrav
Temperatur vid drift 0 - 40
Intervall för relativ operativ luftfuktighet 0 - 95

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.