CyberPower PP1100SW

CyberPower PP1100SW bruksanvisning

(1)
  • Professional Tower UPS
    PP800/PP1100/PP1500T
    User Manual
    K01-P1K50I0
    SAFETY WARNINGS
    (SAVE THESE INSTRUCTIONS)
    This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit.
    Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
    This equipment can be operated by any individuals with no previous training.
    The socket-outlet shall be installed near the equipment and easily accessible.
    During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not
    exceed 3.5mA.
    Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible
    through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the
    battery when maintenance or service work inside the UPS is necessary.
    Do not dispose of batteries in a fire, the battery may explode.
    Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.
    INSTALLING YOUR UPS SYSTEM
    UNPACKING
    Inspect the UPS upon receipt. The box should contain the following:
    UPS Unit¯1; PowerPanel Plus Software Disk¯1; Serial Interface Cable (DB-9)¯1; USB Device Cable¯1;Telephone Cable¯1; User
    Manual¯1; PowerPanel Plus Software User Manual¯1.
    HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
    1. Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated capacity (800VA/550W for
    PP800, 1100VA/700W for PP1100, 1500VA/1000W for PP1500T). If rated unit capacities are exceeded, an overload condition may occur
    and cause the UPS unit to shut down or the circuit breaker to trip.
    2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert Watts (W) or Amps (A) into VA by doing
    the calculations below. Note: The below equation only calculates the maximum amount of VA that the equipment can use, not what is
    typically used by the equipment at any one time. Users should expect usage requirements to be approximately 60% of below value.
    TO ESTIMATE POWER REQUIREMENTS
    1. Watts (W) x 2.0 = VA or Amps (A) x 120 = VA
    2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual requirements. There are many factors that can
    affect the amount of power that your computer system will require. The total load that you will be placing on the battery-powered outlets
    should not exceed 80% of the unit’s capacity.
    HARDWARE INSTALLATION GUIDE
    1. Connect the equipment to your UPS outlets. Items such as copiers, laser printers, vacuums, space
    heaters, paper shredders, or other large electrical devices should not be connected to the UPS.
    Please assure that the total loads of your equipments must be less than the maximum total power
    load of your UPS.
    2. Connect your UPS power cord into a two-pole, three-wire grounding receptacle only. Please avoid
    using extension cords and adapter plugs. (To maintain optimal battery charge, leave the UPS
    plugged in at all times.)
    3. Press the UPS power button to turn it on. The “Power On” indicator will be illuminated in “Green”.
    4. Install your optional software and accessories. To use the software, simply connect the enclosed
    serial interface cable to the serial port on the UPS and an open serial port on the computer.
    BASIC OPERATION
    FRONT PANEL DESCRIPTION
     Power Switch
    Press the ON/OFF button to turn the UPS on or off.
     Power On Indicator
    This LED is illuminated when the utility condition is normal and the UPS outlets are
    providing “clean power”, free of surges and spikes.
     Using Battery Indicator
    This illuminates during utility failure, indicating that the battery is supplying power to the battery-power supplied outlets.
     Boost Indicator
    This LED indicates that the UPS is operating in automatic voltage regulation mode. When this indicator is flashing/
    illuminated continuously, it indicates that the UPS is compensating MAX.14%/ 30% for a low utility voltage.
     Buck Indicator
    This LED indicates that the UPS is operating in automatic voltage regulation mode. When this indicator is illuminated
    continuously, it indicates that the UPS is compensating MAX.12% for a high utility voltage.
    REAR PANEL DESCRIPTION
     Battery Backup and Surge Protection Outlets
    The UPS provides 4 battery powered and surge protected outlets for connected equipment to insure temporary
    uninterrupted operation during a power failure and against surges and spikes.
     Surge Protection Outlets
    The UPS provides 3 surge protected only outlets for connected equipments against surges and spikes.
     Serial/USB Port to PC
    This port allows connection and communication from the DB-9 serial or USB port on the computer to the UPS unit. The
    UPS communicates its status to the PowerPanel Plus™ software. This interface is also compatible with the UPS service
    provided by Windows 98, Windows ME, Windows NT, Windows 2000, Windows XP, Windows Server 2003 and Mac
    OS 10X.
    NOTE: Only one of these two ports can be used as communication and control of the UPS unit at one time.
     Ethernet (RJ-45) Network Protection Ports
    These ports are the protection for your computer network device.
    BATTERY REPLACEMENT AND STORAGE
    Contact your dealer or call the number in this manual for information on battery replacement.
    Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of
    personnel knowledgeable of batteries and their precautions. Keep unauthorized personnel away from batteries.
    CAUTION! Use only the specified type of battery. See your dealer for replacement batteries.
    CAUTION! The battery may present the risk of electrical shock. Do not dispose of batteries in a fire, as it may explode. Follow all local
    ordinances regarding proper disposal of batteries.
    CAUTION! Do not open or mutilate the batteries. Release electrolyte is harmful to the skin and eyes and may be toxic.
    CAUTION! A battery can present a high risk of short circuit current and electric shock. Take the following precautions before replacing the
    battery:
    1. Remove all watches, rings or other metal objects.
    2. Only use tools with insulated handles.
    3. DO NOT lay tools or other metal parts on top of battery or any battery terminals.
    4. Wear rubber gloves and boots.
    5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source of ground. CONTACT WITH A GROUNDED
    BATTERY CAN RESULT IN ELECTRICAL SHOCK! The likelihood of such shock will be reduced if such grounds are removed during
    installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit).
    STORAGE:
    First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected to the UPS to avoid battery drain. To
    store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to insure
    battery life. If the battery remains uncharged for an extended period of time, it may suffer permanent loss of capacity.
    TROUBLE SHOOTING
    Problem Possible Cause Solution
    Batteries are not fully charged.
    Recharge the battery by leaving the UPS plugged in.
    The UPS does not perform
    expected runtime.
    Battery is slightly worn out.
    Contact CyberPower Systems at tech@cyberpowersystems.com.
    The on/off switch is designed to
    prevent damage by rapidly
    turning it off and on.
    Turn the UPS off.
    Wait 10 seconds and then turn the UPS on.
    The unit is not connected to an
    AC outlet.
    The unit must be connected to a 110/120v 60Hz outlet.
    The battery is worn out.
    Contact CyberPower Systems at tech@cyberpowersystems.com.
    The UPS will not turn on.
    Mechanical problem.
    Contact CyberPower Systems at tech@cyberpowersystems.com.
    Circuit breaker is tripped due to
    overload
    Turn the UPS off and unplug at least one piece of equipment. Wait 10
    seconds, reset the circuit breaker and then turn the UPS on.
    Batteries are discharged
    Allow the unit to recharge for at least 4 hours.
    Outlets do not provide
    power to equipment
    Unit has been damaged by a
    surge or spike.
    Contact CyberPower Systems at tech@cyberpowersystems.com.
    The serial cable is not
    connected.
    Connect the serial cable to the UPS unit and an open serial port on the back
    of the computer. You must use the cable that came with the unit.
    The serial cable is connected to
    the wrong port.
    Check the back of the computer for an additional serial port. Move the
    cable to this port.
    The unit is not providing battery
    power.
    Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the
    UPS back on. This should reset the unit.
    PowerPanel Plus™ is
    inactive (all icons are gray).
    The serial cable is not the cable
    that was provided with the unit.
    You must use the cable that was included with the unit for the software and
    the unit to be able to communicate.
    TECHNICAL SPECIFICATIONS
    Model PP800 PP1100 PP1500T
    Capacity (VA) 800VA 1100VA 1500VA
    Capacity (Watts) 550W 700W 1000W
    Input
    Input Voltage Range 85Vac-150Vac
    Frequency Range
    50/60 Hz +/- 3Hz
    Output
    On Battery Output Voltage Pure Sine Wave at 120Vac +/- 7%
    On Battery Output Frequency 47-53Hz for 50Hz nominal, 57-63Hz for 60Hz nominal
    Overload Protection On Utility: Circuit Breaker, On Battery: Internal Current Limiting
    Surge Protection and Filtering
    Lightning / Surge Protection Yes
    Network Protection RJ45 (One In/One Out)
    Physical
    Total # of UPS Receptacles (7) NEMA 5-15R
    Maximum Dimensions 30.9cm*14.1cm*18.4cm
    Weight (Kg) 12.8 14.6 15.5
    Battery
    Sealed Maintenance Free Lead Acid Battery 12V / 8AHx2 12V / 10AHx2 12V / 10AHx2
    Hot Swappable Battery Yes
    Typical Recharge Time 8 Hours
    Warning Diagnostics
    Indicators Power On, Using Battery, Boost, Buck
    Audible Alarms On Battery, Low Battery, Overload
    Environmental
    Operating Temperature +32°F to 95°F ( 0°C to 35°C )
    Operating Relative Humidity 0 to 95% NON-CONDENSING
    Communication
    PowerPanel Plus
    TM
    Software Windows 98/ME/2000/NT/XP, Server 2003, Mac OSX, Linux
    Management
    Auto-Charger/ Auto-Restart/ USB Yes
    SNMP/HTTP Network Optional
CyberPower PP1100SW

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om CyberPower PP1100SW? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av CyberPower PP1100SW att svara på din fråga.

Se manualen för CyberPower PP1100SW helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 9.1. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om CyberPower PP1100SW? Ställ din fråga här

CyberPower PP1100SW – specifikationer

Allmänt
Varumärke CyberPower
Modell PP1100SW
Produkt Avbrottsfri strömförsörjning (UPS)
EAN 649532811007
Språk Engelsk
Filtyp PDF
Egenskaper
Uteffekt kapacitet (VA) 1100
Uteffekt 700
Energivärdering 1796
Ingångsfrekvens 50/60
Svarstid (medel) 4
Hörbart larm
Övrigt
Anslutningsdetaljer utgång NEMA 5-15R
Anslutningsdetaljer ingång NEMA 5-15P
Produktstorlek (BxDxH) 140 x 317.5 x 184
Vikt (imperial) 32
Omgivningstemperatur vid drift 32 - 95
Dimension (B x D x H) (imperial) 5.5 x 12.5 x 7.25
Batteri
Normal drifttid vid halv belastning 18
Normal drifttid vid full belastning 7
Utbytbara batteripatroner BB - BP10-12
Anslutningar
Seriella portar 1
Modem (RJ-11) portar 1
Antal LAN (RJ-45) anslutningar 1
Antal USB 2.0 anslutningar 1
Vikt & dimension
Vikt 14514
Miljökrav
Temperatur vid drift 0 - 40
Intervall för relativ operativ luftfuktighet 0 - 95
Design
Certifiering UL1778, cUL, FCC DOC Class B

Bruksanvisni.ng

Letar du efter en manual? Bruksanvisni.ng säkerställer att du hittar manualen som du letar efter på nolltid. Vår databas innehåller mer än 1 miljon PDF-manualer från över 10 000 märken. Varje dag lägger vi till de senaste manualerna så att du alltid hittar produkten du letar efter. Det är väldigt enkelt: ange bara märket och typen av produkt i sökrutan för att omedelbart semanualen du önskar online helt gratis.

Bruksanvisni.ng

© Copyright 2020 Bruksanvisni.ng. All Rights Reserved.

Vi använder cookies för att se till att vi ger dig den bästa upplevelsen på vår hemsida. Om du fortsätter att använda den här webbplatsen kommer vi att anta att du godkänner detta.

Läs mer