Emerson 1F85CA-0471 bruksanvisning

Emerson 1F85CA-0471
(1)
  • Sidantal: 12
  • Filtyp: PDF
1

Blue Universal Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump
Installation and Operating Instructions for Model:
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
Save these instructions for future use!

APPLICATIONS

SPECIFICATIONS

Electrical Rating:
Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ................................................... 20 to 30 VAC
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ......................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................... Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-20° to +65°C)
Dimensions Thermostat ............................................ 4.0”H x 5.11”W x 1.3”D
www.white-rodgers.com
1F85CA-0471 Thermostat
Model Programming Choices
1F85CA-0471
5/1/1 Day 5/2 Day Non-Programmable
1F85-0471
5/1/1 Day 5/2 Day Non-Programmable
1F83-0471
Non-Programmable
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product
may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any spilled
mercury and place in a sealed container. For proper disposal
of a product containing mercury or a sealed container. Refer
to www.white-rodgers.com for location to send product
containing mercury.
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (with Aux. or Emergency Heat) Yes
Systems with up to 2 Stages Heat, 2 Stages Cool Yes
Heat Only Systems (with optional fan switch) Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces Yes
Cool Only Systems Yes
Gas or Oil Heat Yes
Electric Furnace
Ye s
Hydronic (Hot Water) Zone Heat – 2 Wires Yes
Hydronic (Hot Water) Zone Heat – 3 Wires Yes
Compressor with Comfort Alert II Module (1F85CA only) Yes
Index Page
Installation 2
Wiring Connections 2
Wiring Diagrams 3
Thermostat Quick Reference 4
Installer Confi guration Menu 5
Operating Your Thermostat 7
Programming 7
Troubleshooting 9
PART NO. 37-6920B
Replaces 37-6920A
0905
Emerson 1F85CA-0471

Behöver du hjälp?

Antal frågor: 0

Behöver du hjälp eller har du en fråga om Emerson 1F85CA-0471? Ställ din fråga här. Lämna en tydlig och omfattande beskrivning av ditt problem och din fråga. Ju mer information du anger desto enklare blir det för andra ägare av Emerson 1F85CA-0471 att svara på din fråga.

Se manualen för Emerson 1F85CA-0471 helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 8. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om Emerson 1F85CA-0471? Ställ din fråga här

Emerson 1F85CA-0471 – specifikationer

Allmänt
Varumärke Emerson
Modell 1F85CA-0471
Produkt Termostat
Språk Engelsk
Filtyp PDF

Vanliga frågor

Nedan hittar du de vanligaste frågorna om Emerson 1F85CA-0471 .

Är din fråga inte listad? Ställ din fråga här