BATTERY

SERVICE AND REPAIR

This programmer is NOT user serviceable. Please do not dismantle the unit.

In the unlikely event of a fault developing please refer to the RESETTINGTHEPROGRAMMERsection of
this user guide located on page 2. If this fails to resolve the problem please contact a local heating

engineer or a qualified electrician.

QUESTIONSANDANSWERS
The display only reads bAt
The unit display has become frozen
The indicator neon fails to illuminate on
Zone 1 or Zone 2
The indicator neon will illuminate but the
Zone fails to operate
There is no display on the
programmer
How do I know if the programmer is still
under warranty
How is the programmer removed from
the wall
When setting the programme times, the
setting ‘bounces’ by 10 minute periods
Turn the battery on.The switch on the rear of the unit must be in either the Fully
Pumped or Gravity position.
This could be due to local electrical interference
Using the RESET procedure may rectify the fault.
Using the RESET procedure may rectify the fault. If the problem persists the programmer
will need replacing.
This may indicate a problem elsewhere in your system;
E.g. A zone valve, etc. please contact a registered installer for advice.
Try the RESET procedure on page 2, if this fails to rectify the problem please have the
mains supply checked
The ChannelPlus XL range comes with a 5 year guarantee from the date of manufacture.
This date is located on the rear of the unit, indicated by a month over a year
WARNING: The ChannelPlus programmer must only be removed from it’s backplate by
either a qualified electrician or heating engineer; The programmer plugs in to a 9 pin
backplate located on the rear of the unit and is secured using 2 screws located on the
top surface of the unit. Undo these screws and pull forward and down in an arc motion
This indicates that you have reached an existing set time period, you will be unable to
set a new ON/OFF time unless there is an alteration to the existing timed period
LEAFLET No P32635
ISSUE 3
Page 4

The following are some of the easy to operate features:-

Flexible 7 Day Control

1 or 2 Hour Boost on each channel

Independent timing on Zone 1 and Zone 2

Advance control gives instant On/Off override

Up to 3 On/Off periods per channel in each 24 Hr operation.

Programme options: Auto / All day / On constantly / Off

FULLY PUMPED OR GRAVITY SYSTEM

The installer will have set the programmer to suit the installed system. If this is a Fully pumped
system this will allow independent control of Zone 1 and Zone 2, however on a Gravity system Zone 1
and zone 2 are linked so that it is not possible to use Zone 2 independently. This will allow only one

common time setting for both Zone 1 and Zone 2.

The programmer is fitted with a non-rechargeable, long life battery, which will maintain the

programmed time settings for a minimum of ten months with the supply disconnected.

THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank, after 3 days the current time of day will be lost.
If the programmer is not to be used for a long period of time, the switch on the rear of the unit
should be returned to the BATTERYOFF position. These are both to prolong the battery life.
Horstmann’s ChannelPlus H27ZXL - Two Channel Programmer Offers up to
three programmed operating periods per day, seven days a week, with

independent Boost and Advance control on Fully Pumped Systems.

16 SET slider switch
17 SET Positions

Internal Slide Switch -

located under front cover

17

16

LCD DISPLAYFEATURES
1 Current TIME OF DAY
2 Day of Week Indicator
3 Switch time SETTING indicator
4 ADVANCE symbol
5 BOOST symbol
6 Current Zone 1 programme
7 Current Zone 2 programme
8 Next Zone 2 switch time
9 Next Zone 1 switch time
LED INDICATOR
10 Zone 2 ON indicator
11 Zone 1 ONindicator
EASY TOUSE PROGRAMMEANDFEATUREBUTTONS
12 Zone 2 ADVANCE(ENTER) button
13 Zone 1 ADVANCE (PLUS) button
14 Zone 2 BOOST(COPY) button
15 Zone 1 BOOST (MINUS)button
Both the Zone 1 and Zone 2 SELECT buttons are
located under the front cover
1
5
4
3 2
8
7
9

10

12

11

14

13

15

Page 1
6

Horstmann Controls Limited

Bristol

BS4 1UP

Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk

Se manualen för Horstmann ChannelPlus H27ZXL helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 7.5. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om Horstmann ChannelPlus H27ZXL? Ställ din fråga här

Behöver du hjälp?

Har du en fråga om Horstmann som inte besvarats i manualen? Ställ din fråga här. Ge en heltäckande beskrivning av problemet och formulera din fråga så tydligt som möjligt. Ju tydligare problemet beskrivs och frågan ställs, desto enklare är det för andra Horstmann -ägare att ge dig ett bra svar.

Antal frågor: 0

Allmänt
Horstmann
ChannelPlus H27ZXL
Termostat
Engelsk
Användarmanual (PDF)

Hittar du inte svaret på din fråga i manualen? Svaret kan finnas här nedan i vanliga frågor gällande Horstmann ChannelPlus H27ZXL.

Är din fråga inte listad? Ställ din fråga här

Inga resultat