off two electrical devices (e.g. lights, fans, etc ...).
The module can be controlled either through
Z-Wave network or through the wall switches.
The module is designed to be mounted inside a
“flush mounting box”, hidden behind a traditional
wall switch.
Module measures power consumption of two
electrical devices and supports connection of
digital temperature sensor. It is designed to act
as repeater in order to improve range and
stability of Z-wave network.
Supported switches
Module supports mono-stable switches (push
button) and bi-stable switches. The module is
factory set to operate with bi-stable switches.
Installation
Before the installation disconnect power
supply.
Connect the module according to electrical
diagram.
Locate the antenna far from metal elements
(as far as possible).
Do not shorten the antenna.
Danger of electrocution!
Module installation requires a great degree of
skill and may be performed only by a qualified
and licensed electrician.
Even when the module is turned off, voltage
may be present on its terminals. Any works
on configuration changes related to
connection mode or load must be always
performed by disconnected power supply
(disable the fuse).
Note!
Do not connect the module to loads exceeding
recommended values. Connect the module only
in accordance to the below diagrams. Improper
connections may be dangerous.
Package contents
Flush 2 relays
Electrical diagram 230VAC
Notes for the diagram:
Electrical diagram 24VDC
Notes for the diagram:
Durability of the device depends on applied load.
For resistive load (light bulbs, etc.) and 4A
current consumption of each individual electrical
device, the durability exceeds 70.000 switches of
each individual electrical device.
Module Inclusion (Adding to Z-Wave
network)
Connect module to power supply (with
temperature sensor connected - if
purchased),
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main controller,
auto-inclusion (30 minutes after connected
to power supply) or
press service button S for more than 2
second or
press push button I1 three times within 3s
(3 times change switch state within 3
seconds)
Module Exclusion/Reset (Removing
from Z-Wave network)
Connect module to power supply
bring module within maximum 1 meter (3
feet) of the main controller,
enable add/remove mode on main controller,
press service button Sfor more than 6
second or
press push button I1 five times within 3s (5
times change switch state within 3 seconds)
in the first 60 seconds after the module is
connected to the power supply.
By this function all parameters of the module are
set to default values and own ID is deleted.
If service button S is pressed more than 2 and
less than 6second module is excluded, but
configuration parameters are not set to default
values
Association
Association enables Flush 2 relays module to
transfer commands inside Z-Wave network
directly (without main controller) to other Z-Wave
modules.
Associated Groups:
Group 1: basic on/off (triggered at change of the
output Q1 state and reflecting its state) up to 16
nodes.
Group 2: basic on/off (triggered at change of the
output Q2 state and reflecting its state) up to 16
nodes.
Group 3: default reporting group (reserved for the
main controller).
Configuration parameters
Parameter no. 1 – Input 1 switch type
Available configuration parameters (data type is
1 Byte DEC):
default value 1
0 mono-stable switch type (push button)
1 bi-stable switch type
Parameter no. 2 – Input 2 switch type
Available configuration parameters (data type is
1 Byte DEC):
default value 1
0 mono-stable switch type (push button)
1 bi-stable switch type
Parameter no. 10 - Activate / deactivate
functions ALL ON/ALL OFF
Available configuration parameters (data type is
1 Byte DEC):
default value 255
255 - ALL ON active, ALL OFF active.
0 - ALL ON is not active ALL OFF is not
active
1 - ALL ON is not active ALL OFF active
2 - ALL ON active ALL OFF is not active
On/Off module responds to commands ALL ON /
ALL OFF that may be sent by the main controller
or by other controller belonging to the system.
Parameter no. 11 - Automatic turning Off relay
Q1 after set time
Available configuration parameters (data type is
2 Byte DEC):
Default value 0
0 - Auto OFF disabled
1- 65535 = 10mseconds – 655,35 seconds.
Auto OFF enabled, with define time, step is
10mseconds.
Parameter no. 12 - Automatic turning Off relay
Q2 after set time
Available configuration parameters (data type is
2 Byte DEC):
Default value 0
0 - Auto OFF disabled
1- 65535 = 10mseconds – 655,35 seconds.
Auto OFF enabled, with define time, step is
10mseconds.
Parameter no. 30 - Saving the state of the
relays Q1 and Q2 after a power failure
Available configuration parameters (data type is
1 Byte DEC):
default value 0
0 – Flush 2 relays module saves its state
before power failure (it returns to the last
position saved before a power failure)
1 - Flush 2 relays module does not save the
state after a power failure, it returns to "off"
position.
Parameter no. 40 – Power reporting in Watts
on power change for Q1
Set value means percentage, set value from 0 –
N
+VDC
L
-VDC
Q1
Output for electrical device no. 1
Q2
Output for electrical device no. 2
I2
Input for switch to control electrical
device no.2
I1
Input for switch to control electrical
device no.1
TS
Terminal for digital temperature sensor
(only for Flush 2 relays module
compatible digital temperature sensor,
which must be ordered separately).
N
Neutral lead
L
Live lead
Q1
Output for electrical device no. 1
Q2
Output for electrical device no. 2
I2
Input for switch to control electrical
device no.2
I1
Input for switch to control electrical
device no.1
TS
Terminal for digital temperature sensor
(only for Flush 2 relays module
compatible digital temperature sensor,
which must be ordered separately).
S
Service button (used to
add or remove module
from the Z-Wave
network).
Se manualen för Qubino ZMNHBA2 power relay helt gratis här nedan. Den här manualen tillhör kategorin och har betygsatts av 1 personer med ett genomsnitt på 6.5. Den här manualen är tillgänglig på följande språk: Engelsk. Behöver du hjälp eller har du en fråga om Qubino ZMNHBA2 power relay? Ställ din fråga här